Chlorine Production - BSV PRO200 Manual De Usuario

Ocultar thumbs Ver también para PRO200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

It is possible to select cleaning intervals from 1 to 8 hours.
4.1.6- Chorine menu
With this menu you can select all parameters related to chlorine production.

4.1.6.1- Chlorine production

Configuration of the maximum production of chlorine.
From 0% to 100% Press "OK" and use the arrows   to change the value.
Press "OK" to confirm the adjustment.
Note: Chlorine production may be limited regardless of the operation mode
(manual, automatic...) that is selected.
4.1.6.2- Adjustment of the set value (Max. PPM)
En el cual se instala una sonda de cloro libre (OPCIONAL)
In this case, adjust the value in ppm as required. A value between 1ppm and
1.5ppm is correct.
NOTE: if working in automatic, you can also adjust the production percentage
from 0% to 100%,
On connecting the equipment in automatic mode, the ORP value will
flash for 5 min before the equipment starts to produce chlorine.
4.1.6.3- Free chlorine probe calibration
If you have a free chlorine probe, a menu will appear for you to calibrate it.
46 / 53
Manual PRO v.2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Pro250Pro500Pro750Pro1000

Tabla de contenido