Installing Accessories - Greenlee FishFinder Plus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation
Installing or Removing Batteries
Electric shock hazard:
Before opening the case or battery compartment, remove the tool from the circuit and shut off
the unit.
Failure to observe this warning could result in severe injury or death.
1. Remove the unit from the circuit. Turn the unit off.
2. Depress the battery door latch to remove the battery door cover.
3. Install or replace the batteries (observe polarity as indicated on the battery compartment).
4. Replace the battery door cover and snap into place.
Installing the 56270 CAT IV Optical Cable
To use the FF200 inspection device, the 56270 CAT IV optical cable must be connected to the
handheld device. To connect the cable to the handheld device, make sure the key and slot
configuration are properly aligned (refer to figure below). Once they are aligned, hand-tighten the
knurled nut to hold the connection in place.

Installing Accessories

All three of the included accessories (hook, magnet, and mirror) attach to the optical cable head in
the same way.
Electric shock hazard:
• Never make bodily/personal contact beyond the retention shield located at the base of the
optical cable connector when in use on or near potentially energized objects.
• To avoid electrical shock, the hook, magnet, or mirror must be used on de-energized circuits
only. The hook, magnet, and mirror accessories are made from steel and will conduct
electricity. Usage of these accessories nullifies the electrical safety compliance of the optical
cable.
• Do not expose to corrosive chemicals.
Failure to observe these warnings could result in severe injury or death.
Key
Slot
FF200
7

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ff200

Tabla de contenido