Note: To Equipment Provider: The following oxygen
administration accessories are recommended for
use with the Oxygen Concentrator:
• Nasal Cannula with 7 feet (2.1 m) of tubing:
CU002-1
• For any additional recommended accessories,
please see the Accessories Catalog (PN ML-
LOX0010) available on www.CAIREmedical.com.
A firebreak is required for use with any cannula.
• CAIRE offers the OxySafe™. This is intended to be
used in conjunction with the oxygen concentrator.
The OxySafe™ is a thermal fuse to stop the flow of
gas in the event that the downstream cannula or
oxygen tubing is ignited and burns to the OxySafe.
It is placed in-line with the nasal cannula or oxygen
tubing between the patient and the oxygen outlet
of the NewLife.
For proper use of the OxySafe, always refer to the
manufacturer's instructions (included with each
OxySafe kit).
CAIRE offers an OxySafe™ kit that includes a
cannula headpiece, OxySafe™, and 7' tubing: PN
20629671.
Specifications
Flow Rates*
Dimensions
Weight
Sound Pressure
Level
Power
Consumption
O2 Concentration
Output Pressure
NewLife Elite
1–5 LPM (±10% of indi-
cated setting, or 200 mL,
whichever is greater)
28.5 x 15.7 x 14.5 in
(72.4 x 40.0 x 36.8 cm)
54 lbs (24.5 kg)
48 dB(A) at flow rates of 1
to 5 LPM
350 watts–1-5 lpm model
Two-prong polarized plug
Double insulated cabinet
North American Models:
120 VAC, 60 Hz, 4.0 amps
Export Models:
230 VAC, 50 Hz, 2.0 amps
230 VAC, 60 Hz, 2.0 amps
1-3 lpm: 95.5% - 92.0%
4 lpm: 92% ± 3%
5 lpm: 90% ± 3%
7 psi (48 kPA)
NewLife Family
WARNING: KEEP OUT OF THE REACH
OF CHILDREN UNTIL INSTALLED.
WARNING: CET APPAREIL PRODUIT
DE L'OXYGÈNE À CONCENTRATION
ÉLEVÉE, FAVORISANT UNE COMBUS-
TION RAPIDE. NE PAS PERMETTRE
DE FUMER OU DES FLAMMES NUES
DANS LA MÊME CHAMBRE: (1) CET
APPAREIL OU (2) TOUT ACCESSOIRE
CONTENANT DE L'OXYGÈNE. NE
PAS UTILISER DE PRODUITS À BASE
D'HUILE, DE GRAISSE OU DE PÉTROLE
SUR OU À PROXIMITÉ DE L'UNITÉ.
DÉCONNECTER LE CORDON D'ALI-
MENTATION DE LA PRISE ÉLECTRIQUE
AVANT DE NETTOYER OU DE FAIRE
L'ENTRETIEN DE L'UNITÉ.
RISQUE DE CHOC ÉLECTRIQUE. NE PAS
ENLEVER LES COUVERCLES LORSQUE
L'UNITÉ EST BRANCHÉE. SEULS VOTRE
FOURNISSEUR D'ÉQUIPEMENT OU UN
TECHNICIEN DE SERVICE QUALIFIÉ
DEVRAIT ENLEVER LES COUVERCLES
OU FAIRE L'ENTRETIEN DE L'UNITÉ.
NewLife Intensity 8
2–8 LPM (±10% of indi-
cated setting, or 200 mL,
whichever is greater*)
27.5 x 16.5 x 14.5 in
(69.9 x 41.9 x 36.8 cm)
54 lbs (24.5 kg)
52 dB(A) at flow rates of 1
to 8 LPM
410 watts–2-8 LPM model
Two-prong polarized plug
Double insulated cabinet
North American Models:
120 VAC, 60 Hz, 4.0 amps
Export Models:
230 VAC, 50 Hz, 2.0 amps
230 VAC, 60 Hz, 2.0 amps
2–7 LPM: 92%+3.5%/-
3%, 8 LPM: 90%+5.5%/-
3%)
20 psig (138 kPA)
NewLife Intensity 10
2–10 LPM (±10% of indi-
cated setting, or 200 mL,
whichever is greater*)
27.5 x 16.5 x 14.5 in
(69.9 x 41.9 x 36.8 cm)
58 lbs (26.3 kg)
55 dB(A) at flow rates of 1
to 10 LPM
600 watts–2-10 LPM
model
Two-prong polarized plug
Double insulated cabinet
North American Models:
120 VAC, 60 Hz, 6.0 amps
Export Models:
230 VAC, 50 Hz, 3.0 amps
2–9 LPM: 92%+3.5%/-
3%, 10 LPM: 90%+5.5%/-
3%
20 psig (138 kPA)
PN MN239-C4 A | User Manual
ENG - 9