(MH-0135-0M10/MH-0190-0M10/MH-0215-0M10 only) will light and the
heater will start.
NOTE: The room temperature display (MH-0135-0M10/MH-0190-0M10/MH-0215-0M10
only) will indicate the following:
•
When temperature is less than 0° F, display says "LO".
•
When temperature is above 99° F, display says "HI".
•
Between 0° and 99° F display shows actual temperature.
If the heater does not fire, the thermostat may be set too low. Turn the
Control Knob to a higher setting until heater fires. If the heater still does not start, push Power Switch to
"OFF", then back to "ON". If heater still does not fire, see Troubleshooting Guide.
NOTE: The electrical components of this heater are protected by a fuse mounted in the PC board. If the heater fails to fire,
check this fuse first, and replace if necessary. Also check the power source to be sure that the proper voltage is being
provided to the heater.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
Note: Using Diesel fuel can cause excess soot production
TO STOP THE HEATER
Simply turn the Power switch to "OFF" posi-
tion and unplug the Power Cord.
TO RESTART THE HEATER
1. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to "ON" position.
3. Be sure to follow all starting procedure
precautions.
LONG TERM STORAGE
DRAIN FUEL TANK
For model MH-0075-0M10, drain fuel through the fuel cap opening. For models MH-0135-0M10/MH-
0190-0M10/MH-0215-0M10, drain fuel through the Drain Plug at the bottom of the Fuel Tank.
1. To remove the Drain Plug (MH-0135-0M10/MH-0190-0M10/MH-0215-0M10), pull the Plug Grip downward
and remove seal head from drain hole in tank.
2. Using a small amount of
kerosene, rinse and swirl the
kerosene inside of the Fuel
Tank. Empty the tank fully.
3. To replace, push the drain head
fully into the drain hole and
secure by pushing the seal cap
fully into the head hole.
IMPORTANT: Never store leftover
kerosene over the summer.
Using old fuel can damage
your heater.
Store heater in a dry, well-
ventilated area Be sure that
the storage area is free of
dust and corrosive vapors.
Repack the heater in the original shipping material. Keep the Users Manual in an easily accessible place.
14
OPERATION
MH-0135-0M10 / MH-0190-0M10 / MH-0215-0M10 ONLY
Plug Grip
Drain Plug
Power Switch
Storage Drawer
Electrical Outlet
Kerosene Portable Heaters Manual
Drain Plug
Fuel Tank
Seal Head
Head Flange
Head Flange
Cap Flange
Seal Cap