After having connected the heat pump to the pool water circuit system trough a suitable by-pass and having made
the electrical connections by a qualified engineer, please verify the following points:
Appliance is in a horizontal position and on a solid ground.
Water circuit is primed (full of water): no air inside the tubes or the heat pump tank.
Water circuit is well connected (no leaks and no chance of injury due to badly fitted hydraulic couplings).
Electrical circuit is well connected (all cables tightened correctly at terminals and intermediate circuit breaker),
insulated and earthed correctly.
The installation requirements described previously are strictly adhered to.
Ambient temperature is between : 0°C and + 35°C
Water temperature is between 15 and 30°C (50°F and 86°F).
You can then start up your machine. Follow the instructions below in the given order each time you start up
the pool heat pump, especially at the beginning of the swim season:
Open the three by-pass valves and then half close the settings valve
Start the pool pump
Turn on the pool heat pump with the on/off switch (turn it to « I »).
Check the machine to make sure that it starts only together with the filtration pump: If the filtration pump is not
working, the controller will shows "EE3".
The pool heat pump will work after a delay of few minutes.
Set regulation (Chapter «Regulation»).
Set heating (Chapter «Heating»).
After a few minutes (time for circuit to heat itself) you can regulate water flow as explained hereafter (Chapter
"Water flow regulation")
After these operations, you must put your pool cover on the swimming pool and let the heat pump work for few
days in order for the water temperature to increase to the desired temperature.

Setting of digital controller

Press
ON/OFF the unit
Press
the mode
cooling/heating
Note: Please do not forget to close the waterproof box after finishing the setting of the wired controller.
to turn
to change
By-pass diagram
Press
to set and check
parameters
- 22 -
Press
to set timer