Starting the Heater (Ignition):
1. Fill the tank with Kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that is
at least 1.8 meters long and is a minimum of 14
AWG rating.
NOTE: On first ignition or after refueling, you may
hear a grinding sound just before ignition. This is
the fuel pump removing the air from the fuel line.
Your heater will start up within seconds. If it does
not start repeat
start-up procedures with fuel gauge reading at
least 1/2 tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these
heaters are protected by a fuse mounted in the
PC board. If the heater fails to ignite, check this
fuse first and replace if necessary. Also check the
power source to be sure the proper voltage is
being provided to the heater.
1. Complete steps 1-3 above.
2. Push the power switch to the "ON" position.
The power indicator lamp will light and heater
will ignite (see Figure 10).
Figure 10
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
Stopping the Heater (Cool Down):
1. Turn the power switch to the "OFF" position.
NOTE: Unplugging the heater before the Cooling
Cycle has been completed may cause overheating,
possible damage to the heater and heat plate.
cooling cycle has been completed.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has
2. Follow all start-up procedures above.
Electrical Outlet (80-OFR Only):
-
-
Power Switch
Figure 11
8
Combustion will stop and the Cooling Cycle
will begin.
- 80-OFR: approx. 5 mins
- 125-OFR-A: approx 3 mins
When the Cooling Cycle is complete the fan
will stop running and it will be safe to unplug
the heater.
WARNING
been completed.
Never plug an appliance with more than a 5
amp rating into this outlet (see Figure 11).
Always keep outlet covered when not in use
Kerosene Radiant Heater User's Manual
DO NOT disconnect
heater from power
source before
Electrical Outlet
80-OFR Only