ET Water SmartBox Generation 4 Serie Guía Para La Instalación página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Step 5: Connect cellular antenna
Screw the black cellular antenna (included) onto the ¼" brass fitting on the base of the control-
ler. (For pancake or other vandal-resistant antennas, use the same brass fitting)
Step 6: Make electrical connections
Connect 110 volt AC power and ground in
accordance with all local codes and National
Electrical Codes. Turn circuit breaker on.
Step 7: Initialize controller and Test Dial
Press the TEST DIAL button. A message on
the LCD screen will report the cellular signal
strength. Readings in the range of 10 to 32
should be sufficient, and you will be directed to press ENTER to continue the test dial process.
After a successful connection, the LCD screen will display "Successful Call Complete, " followed by
"ET Water Online" with the correct time and date.
If you receive a signal strength of 1 to 9, make sure the antenna is securely connected.
If the strength still falls in that range, contact customer support. A signal strength of 99
indicates the controller can't connect to the local cell tower. Press EXIT, wait two min-
utes, and press the TEST DIAL button again. If the controller still will not initialize, contact
customer support.
Step 8: Replace outer door
Replace outer door and lock cabinet if desired.
INSTALLATION OF YOUR ET WATER SMART CONTROLLER IS NOW COMPLETE!
WARNING:
If the controller is installed in an area
known to receive lightning strikes, ET
Water recommends the controller be
thoroughly grounded via a grounding
rod or similar installation.
5