lIFT TaBlE CalIBraTION
1. Turn the lift off.
2. Set dip switch 4 to ON
3. Turn the lift on
4. Wait 2 seconds then set dip switch 4 to OFF.
5. Move the lift to the CAL LT point (lift table closed), then press the button on the board.
6. Wait for the message "CALIBRATION OK", then turn the lift off. The integrated lift table
is now calibrated.
REMARKs: the integrated lift table (Lt) is disabled if it has not been calibrated.
112
22_1
P1
dip-sw 4
Operator' s manual