Safety Notes

Gloves should be worn during installation to prevent crushing and cutting
injuries.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The product may only be used for bathing, hygienic and body cleaning pur-
poses.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages.After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Assembly see page 31

Symbol description

Do not use silicone containing acetic acid!
Freestanding tub with outside covering.
Adjustment (see page 32)
To adjust the hot water limiter. Using a hot water limiter in combination
with a continuous flow water heater is not recommended.
Maintenance check valve (see page 34)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Operation (see page 36)
Dimensions (see page 33)
Flow diagram (see page 33)
Hand shower
Bath Spout
Spare parts (see page 35)
Special accessories (see page 35)
extension 60 mm (article number 97686000) order as an extra
extension 60 mm (article number 10981000) order as an extra
Test certificate (see page 36)
Cleaning (see page 34)

Publicidad