English
CAUTION
The selection examples shown in Table 5 should
be considered as a general standard. As different
types of tightening screws and different materials
to be tightened are used in actual works proper
adjustments are usually necessary.
When using the driver drill with a machine screw
at HIGH (high speed), a screw may damage or a
bit may loose due to the tightning torque is too
strong. Use the driver drill at LOW (low speed)
when tightening a machine screw.
NOTE
The use of the battery EB9H in a cold condition
(below 0 degree Centigrade) can sometimes result
in the weakened tightening torque and reduced
amount of work. This, however, is a temporary
phenomenon, and returns to normal when the
battery warms up.
MAINTENANCE AND INSPECTION
1. Inspecting the tool
Since use of as dull tool will degrade efficiency and
cause possible motor malfunction, sharpen or re-
place the tool as soon as abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Fail-
ure to do so could result in serious hazard.
3. Cleaning on the outside
When the driver drill is stained, wipe with a soft
dry cloth or a cloth moistened with soapy water.
Do not use chloric solvents, gasoline or paint thin-
ner, as they melt plastics.
4. Storage
Store the driver drill in a place in which the
temperature is less than 40°C and out of reach
of children.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connection of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue:
– Neutral
Brown:
– Live
As the colours of the wires in the mains lead of this tool
may not correspond with the coloured markings identify-
ing the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except United Kingdom.
8
Information concerning airborne noise and vibration
The measured values were determined according to
EN50144.
The typical A-weighted sound pressure level: 77 dB (A).
Wear ear protection.
The typical weighted root mean square acceleration value
does not exceed 2.5m/s
2
.