GE ADA 18 Instrucciones De Instalación página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARE HOT WATER LINE
NOTE: GE Appliances recommends copper tubing for
the water line, but if you choose to use flexible hose,
use GE Appliances WX28X326, flexible braided hose.
The water supply line (3/8" copper tubing or flexible
braided hose) may enter from either side, rear or
floor within the shaded area shown in the figure.
• The water supply line may pass through the same
hole as the electrical cable and drain hose. Or, cut an
additional 1-1/2" diameter hole to accommodate the
water line. If power cord with plug is used, water line
must not pass through power cord hole.
1-1/2"
Dia.
Hole
Shut-off
Valve
Hot
5"
From
Cabinet
Cabinet Face
Installation Preparation
3"
6"
15" From Wall
3" From Floor
WATER LINE CONNECTION
• If using a flexible braided supply hose, label the
hose with the installation date to use as reference.
Flexible braided hoses, elbows and gaskets should
be replaced in 5 years.
• Turn off the water supply.
• Install a hand shut-off valve in an accessible location,
such as under the sink. (Optional, but strongly
recommended and may be required by local codes.)
• Water connection is on the left side of the dishwasher.
Install the hot water inlet line, using no less than 3/8"
copper tubing or a flexible braided hose. Route the
line as shown in PREPARE HOT WATER LINE and
extend forward at least 19" from rear wall.
• Adjust water heater for 120°F to 140°F temperature.
• Flush water line to clean out debris.
• The hot water supply line pressure must be 20-120 PSI.
PREPARATION
Locate the items in the installation packages:
• Screws
• Drain hose extension
• Mounting brackets
• Literature, product samples and/or coupons
Turn page to begin dishwasher installation.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pdt145sslssGdt225sgl0bbGdt226sslss

Tabla de contenido