4.1 Placement and testing (Fig.2-3)
Observe the wind direction when operating the
power tool outdoors.
– Firstly, carry out a test-spray run and adjust the spray
pattern and the spray material quantity according to the
spray material. (For adjustments, see the following
sections)
– Make sure to hold the spray gun vertical to the spray
object at a uniform clearance between 5–15 cm.
– Begin the spraying procedure outside the target area.
– Move the spray gun evenly cross-wise or upand-down,
depending on the spray pattern
setting. An even surface quality is achieved when the
paths overlap by 4 – 5 cm.
– Avoid interruptions inside the target area.
An even movement of the spray gun results in an even
surface quality. Non-uniform clearance and spray angle
lead to heavy formation of paint mist and thus to an
uneven surface.
– End the spraying procedure outside the target area.
Never spray the container completely empty. When the
suction tube no longer immerses in the spray material, the
spray jet will break off, resulting in a non-uniform surface.
When coating material builds up on the nozzle and air
cap, clean both parts with the corresponding solvent.
Only place down the power tool on a level and clean
surface so that it can not tip over.
Adjusting the Spray Pattern (fig. 4-5-6)
Never actuate the trigger switch 16 while adjusting
the air cap 13-14.
– Loosen the union nut 14.
– Turn the air cap 13 to the requested position.
– Firmly retighten the union nut 14.
4.2 Adjustment operation (Fig.7)
Preparing for Operation
Spraying on the sides of water bodies (lakes, rivers,
etc.) or neighbouring surfaces in the direct catchment
area is not permitted.
When purchasing paint, varnish and spray material, pay
attention to their environmental compatibility.
Preparing the Spray Surface
Cover off the vicinity of the spray surface
thoroughly and generously.
The spray mist contaminates the environment. When
spraying in enclosures, surfaces not covered can become
contaminated. The spray surface must be clean, dry and
grease-free.
– Roughen smooth surfaces and then remove the sanding
dust.
ENGLISH
15
Preparation of material (fig.11)
1. Mix the material well before measuring viscosity.
2. Completely submerge the cup viscometers, in the
material to be sprayed.
3. Hold the cup test and measure time in seconds until all
the liquid is emptied and this corresponds to time (seconds)
depending on the material supplied as appropriate, in the
following table.
Table Preparation of material:
Material
Oil Painting
Oil Primer
Coating

4.3 Correction of Malfunctions

See table page 17 and 18

5. Maintenance and service instructions

Before any work on the machine itself, pull the
mains plug.
5.1 Cleaning (Fig.9)
Never immerse the electrical unit into solvent or water.
Clean the housing using only a moist cloth.
Proper cleaning is the requirement for flawless operation of
the spray gun. Improper or lack of cleaning voids warranty
claims.
Always clean the spray gun and the container with the
respective diluting agent (paint thinner or water) for the
spray material being used.
Never clean the nozzle and air holes of the spray gun with
pointed metal objects. Do not pour diluted spray material
back into the original spray material drum/tin for storage.
Clean the spray gun thoroughly after having sprayed
material hazardous to one's health.
– Unplug the mains plug and pull the trigger switch 16 so
that the spraying material can flow back into the container.
– Remove the electrical unit.
– Unscrew the container 11 and empty the remaining spray
material.
– Fill diluting agent (paint thinner or water) into the container
and screw it to the spray gun.
– Shake the spray gun several times.
– Connect the spray gun to the electrical unit again.
– Plug the mains plug into a socket outlet, pull the trigger
switch and spray the diluting agent into an empty material
tin.
– Repeat the process until clear diluting agent emerges
from the spray gun.
Unplug the mains plug and remove the electrical unit.
15
Time (sec)
25-40
30-45
20-50

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Epg 700

Tabla de contenido