3.3 - POSITIONING OF THE MACHINE (Fig. 3)
DANGER
Make sure that the carrying plane is suitable to
support the charges as mentioned in the chapter
"TECHNICAL SPECIFICATIONS".
The machine shall be positioned by carefully following
the instructions as reported in Fig 3, since they indicate
the minimum distances needed by the user or technician
in order to properly carry out every work and/or
maintenance operation.
3.4 - ELECTRICAL CONNECTION (Fig. 4)
DANGER
•
The power feed line should be provided with a
suitable omnipolar DISCONNECTING SWITCH
(automatic thermomagnetic switch or differential)
placed before the control unit main switch, with
a minimum contact opening of 3 mm.
•
The earthing system should comply with the local
electric regulations in force.
•
The electric power cables should comply with the
maximum current required by the machine, so
that the total voltage drop at full charge will be
less than 2%.
•
The specifications of the electric power line
should correspond to the specifications of the
identification plate and to those mentioned in the
technical specifications table that can be
consulted in the first part of this booklet.
DANGER
Before connecting the machine with the electric line,
make sure that the DISCONNECTING SWITCH is
disconnected (line not energized), therefore:
• Connect the power cable (1) of the machine with the
disconnecting switch placed above.
GB - 12
FIG. 3
400 mm
FIG. 4
1
FX/RB/RVE
Installation and connections
400 mm
400 mm
1000 mm