Threading-On And Setting Of A Blind Rivet Nut; Important - Gesipa GBM 95 Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
6.3

Threading-on and setting of a blind rivet nut

Place the rivet nut in front of the threaded mandrel (2) (see drawing 3) without tilting and
push the thread-on button (35).
Hold the blind rivet nut during the entire threading process until it fits tightly against the
nosepiece (1).
Insert the blind rivet nut into the workpiece, ensuring that the fastener´s head is fully sea-
ted. Next set the blind rivet nut by pressing the stroke button (35).
Hold button (35) until blind rivet nut is set completely.
Release button (35). The threaded mandrel (2) is threaded off automatically.
Drawing 3
Attention!
In order to avoid upsetting smaller or thin-wall type blind rivet nuts during the threa-
ding process, disconnect tool and increase the threaded mandrel protusion to a length
such that the rivet nut does not thread on flush against the nosepiece. Adjust setting
stroke (see paragraph 6.2)

Important:

If the threaded mandrel (2) is not threaded out of the blind rivet nut completely, a short
quick touch of the stroke button (35) will induce threading-out procedure.
If the threaded mandrel is stuck in the blind rivet nut, it may be loosened by means of the
enclosed hexagon wrench SW4 (see drawing 4).
Drawing 4
2
1
35
35