TROUbLESHOOTING
The following symptoms do not indicate malfunction.
Symptom
Mist emerges from indoor unit.
Water flowing sound during operations.
The room has a peculiar odour.
Indoor fan stops occasionally during
automatic fan speed setting.
Operation is delayed a few minutes after
restart.
Outdoor unit emits water/steam.
The unit operates automatically when
power is resumed after a power failure.
Check the following before calling for servicing.
Symptom
Cooling operation is not working efficiently.
noisy during operation.
Remote control does not work.
The unit does not work.
fOR ExTENDED NON-USE
• Activate fan mode for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
SEASONAL INSPECTION AfTER ExTENDED
NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:
Cooling: ≥ 8°C
NON SERvICEAbLE CRITERIAS
TURn OFF POwER SUPPLY and CALL Authorized Distributor under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the Remote Control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
• The timer indicator blinks and the unit can not be operated.
Cause
Condensation effect due to cooling process.
Refrigerant flow inside the unit.
This may due to damp smell emitted by the wall, carpet, furniture or clothing.
This helps to remove the surrounding odours.
The delay is a protection to the unit's compressor.
Condensation or evaporation occurs on pipes.
This is the Auto Restart function of the unit. Operation will be restarted automatically under
the previous operation mode when power is resumed as the operation is stopped due to
power failure.
To cancel the Auto Restart Control, please refer to page 6.
Check
Set the temperature correctly.
Close all doors and windows.
Clean or replace the air filters.
Clear any obstruction at the air inlet and air outlet vents.
Check if the unit has been installed at an incline.
Close the front panel properly.
Insert the batteries correctly.
Replace weak batteries.
Check if the circuit breaker is tripped.
Check if timers have been set correctly.