Primary lithium battery
LS 14500
3.6 V Primary lithium-thionyl chloride (Li-SOCl
High energy density
AA-size bobbin cell
Benefits
Enhanced capacity
●
High voltage response, stable
●
during most of the lifetime of
the application
Wide operating temperature
●
range (- 60 ° C/+ 85 ° C)
Low self-discharge rate
●
(less than 1 % after 1 year of
storage at + 20 ° C)
Easy integration into compact
●
systems
Superior resistance to
●
atmospheric corrosion
Key features
Stainless steel container
●
and end caps
(low magnetic signature)
Hermetic glass-to-metal sealing
●
Non-flammable electrolyte
●
Compliant with IEC 60086-4
●
safety standard and
IEC 60079-11 intrinsic safety
standard (class T3 assignment)
Underwriters Laboratories (UL)
●
Component Recognition
Non-restricted for transport/
●
Non-assigned to Class 9
according to the UN
Recommendations on the
transport of dangerous goods
– Model Regulations
Manufactured in France, UK, China
●
Main applications
Utility metering
●
Automatic meter reading
●
Alarms and security devices
●
Tollgate systems
●
Memory back-up
●
Tracking systems
●
Automotive electronics
●
Professional electronics
●
September 2009
Cell size references
Electrical characteristics
(
typical values relative to cells stored for one year or less at + 30 ° C max.)
Nominal capacity
(at 2 mA + 20 ° C 2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
(at + 20 ° C)
Open circuit voltage
Nominal voltage
(at 0.2 mA + 20 ° C)
Nominal energy
Pulse capability: Typically up to 250 mA
(250 mA/0.1 second pulses, drained every 2 mn at + 20 ° C from
undischarged cells with 10 μA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell's previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(Higher currents possible, consult Saft)
Storage
(recommended)
(for more severe conditions, consult Saft)
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult Saft)
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
CN, CNR
2 PF, 3 PF, 3 PF RP, 4 PF
CNA (AX)
FL
)
2
radial tabs
radial pins
axial leads
flying leads...etc.
R6 - AA
2.6 Ah
3.67 V
3.6 V
9.36 Wh
50 mA
+ 30 ° C (+ 86 ° F) max
- 60 ° C/+ 85 ° C
(- 76 ° F/+ 185 ° F)
14.55 mm (0.57 in)
50.3 mm (1.98 in)
16.7 g (~ 0.6 oz)
approx. 0.7 g