12 | Troubleshooting
Fault
Clamping force is not built up. Minimum clamping width
Spindle can no longer be
turned.
Clamping force cannot be
released.
GRIPP insert is broken.
GRIPP tips are pressed flat.
Spindle does not transmit a
signal.
84 / 474
Cause
reached.
Workpiece clamped laterally
too far off centre
GRIPP tips are twisted.
Coupling is released too early. Check spindle and spindle nut
Power amplifier defective.
After releasing the clamping
force, the coupling has no
longer tangibly locked into
position again.
One GRIPP insert is broken.
Mobile jaw fixed with over-
length screws.
Power amplifier defective.
Torque of 30 Nm exceeded.
Excessive machining forces.
Workpiece clamped with more
than 1000 N/mm², possibly
flame cuts from C 45.
Batteries expended.
Distance between spindle and
receiver too great or shielded.
Remedy
Use different jaws.
Clamp workpiece centrally.
Align GRIPP tips with the
workpiece surface.
for smooth running, remove
corrosion if necessary.
In the event of a worn coup-
ling mechanism, contact ALL-
MATIC Service.
Contact ALLMATIC Service.
Lock spindle into position
again by turning counter-clock-
wise.
Install new rubber scrapers.
Torque of 30 Nm exceeded,
too high machining forces.
Replace GRIPP insert.
Use screws of suitable length
Unscrew pressure plate from
lower section.
Replace GRIPP insert.
Replace GRIPP insert.
Replace batteries.
Reduce distance spindle -
receiver, clear path.
TITAN 2 (CA) Serie
ALLMATIC