Accesories supplied
1
150/ 120 mm reduction.
4
Screws (M4 x 12).
4
Screws (M4 x 10).
6
Lock screws (Ø8 x 45).
Installation
Fig. 1 (Page 43)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
10 are complied with.
To obtain optimum performance, the external
conduct must not be more than FOUR
METRES long, have no more than two 90°
angles and its diameter must be at least Ø120.
1) Using the support (O) trace and drill the
where the screw-fittings will sit onto the roof (S)
(Ø8 x 45).
2) Screw the support (O) into the roof with the
screw-fittings (S) (Ø8 x 45).
3) Mount the upper chassis
support (O) using the screws (Q) (M6 x 16).
4) Connect the upper part of the inner tube (not
supplied) to the exit.
5) Mount the upper cover (A8) and attach it to
the upper chassis (A6) with the screws (G) (M4
x 12).
6) Fit the part (B) if the inner tube (not supplied)
is Ø120.
7) Mount the whole lower unit to the upper
section, attaching it to the roof using the
screws (A10) (M4 x 12) at the required height.
8) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be..
9) Mount the lower part (A9a) of the cover to
the lower chassis (A7) with the screws (I) (M4
x 12).
10) Adjust the lower part (A9b) of the cover
(A9a) as shown in the diagrams.
Active charcoal filters (Optional)
When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active charcoal
filters.
The active charcoal filters have an active life of
between three to six months, depending on
the individual conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.
Fig. 1 (Page 43)
1) Mount the diffuser support (A13) onto the
upper chassis (A6) with the screws (A4) (M4 x
12).
2) Adjust the diffuser (A5) over the support
(A13).
3) Connect the upper part of the inner tube (not
supplied) to the circular support exit (A13).
4) Using the support (O) trace and drill the
where the screw-fittings will sit onto the roof (S)
(Ø8 x 45).
5) Screw the support (O) into the roof with the
screw-fittings (S) (Ø8 x 45).
6) Mount the upper chassis
support (O) using the screws (Q) (M6 x 16).
7) Mount the upper cover (A8) and attach it to
(A6) onto the
the upper chassis (A6) with the screws (G) (M4
x 12).
8) Mount the whole lower unit (A7) to the upper
section, attaching it to the roof using the
screws (A10) (M4 x 12) at the required height.
9) Fasten the inner tube (not supplied) with a
clamp to the air-outlet of the motor.
10) Mount the lower part (A9a) of the cover to
the lower chassis (A7) with the screws (I)
(M4x12).
11) Adjust the lower part (A9b) of the cover
(A9a) as shown in the diagrams.
12) Remove the metal filters. Loosen the
screws of the EASYCLEAN panels (A19) and
take them off.
13) Fit the nut-supports (F) onto the body of the
kitchen hood.
14) Attach the supports (B) with the screws (E)
(M4 x 12) onto the nuts (F).
15) Mount the carbon filters (A) introducing the
anchorages into the grooves of the supports
(B).
16) Fit the metal filters.