Drain Cock
Power Switch
5) OPERATING PROCEDURE
Prior to using the tool, be sure to go through "Inspection/Checking Prior to Operation" on Page
14.
1. Close the drain cock and turn on the Power switch.
2. Once the pressure has increased and operation has stopped, turn the reducing valve
adjusting handle to adjust to the appropriate working pressure of the nail driver/pneumatic
tool.
To adjust the pressure, turn the reducing valve adjusting handle to the left to
decrease the pressure to 2bar lower than the appropriate value. Then, turn the handle to
the right to adjust the pressure, gradually increasing it.
※ When adjusting the pressure, be sure to increase it from lower than the appropriate
pressure. If adjustment is made by decreasing from higher than the appropriate pressure,
there will be an error between the indication of the pressure gauge and actual working
pressure.(Characteristic of the reducing valve)
※ This tool has two reducing valves which can be connected to MAX Powerlite Nailer and a
general nail driver/pneumatic tool.
<Reducing valve H > Can be connected to MAX Powerlite Nailer.
<Reducing valve L > Can be connected to the reguler pressure nailer(working pressure
of 9bar a or lower).
Be sure to observe the working air pressure of the Nailer.
Without adjusting the supply pressure with the reducing valve, using the nail driver/pneumatic
tool could considerably deteriorates its performance, shortens its service life or damage it,
causing danger to you.
※ If the nail driver/pneumatic tool is used at inappropriate pressure(higher than necessary),
more air may be consumed, considerably lowering continuous working performance of
the nail driver/pneumatic tool. Be sure to use it at appropriate pressure.
3. After adjusting the supply pressure, connect an air hose to an air outlet(air chuck). Now,
you are ready to start operating the machine.
14