Clearing the tare
➜ Press
.
The Net indicator goes out, the gross weight appears in the display.
• If automatic clearing of the tare weight is set in the supervisor menu (F1.5.2=On), the
tare weight is cleared automatically as soon as the weighing platform is unloaded.
• If tare interlock is set in the supervisor menu (F1.5.3=On), the tare weight can only be
cleared when the weighing platform is unloaded.
Automatic taring
This function must be activated in the supervisor menu (F1.5.1=On).
➜ Place the empty container on the weighing platform.
The weight applied on the weighing platform is automatically saved as the tare weight.
The zero display and the Net indicator appear.
Printing/transferring data
➜ Press
.
The display contents are printed out or transferred to a computer.
3.5 Notes on battery operation
With a fully loaded new rechargeable battery, you dispose of approx. 35 operating hours.
The
indicator shows the state of the rechargeable battery.
+
–
constantly red
+
–
+
–
slowly blinking, red
+
–
fast blinking, red
green
+
–
3.6 Cleaning
DANGER!
Electric shock hazard due to ingress of moisture!
▲ Before cleaning the weighing terminal, pull out the mains plug to discon-
Approx. 10 % of full voltage
Approx. 5 % of full voltage
Less than 5 % of full voltage,
battery has to be loaded immediately
Battery is loaded.
Loading takes place as soon as the weighing terminal is
connected to the mains.
nect the unit from the power supply.
10