Using the Features

• HOLD Button Press momentarily to hold the present value on the
display.
will appear on the display.
Press again to return to normal mode.
• MAX Button Press momentarily to hold the maximum value on the
display.
on the display, which will update when the meter measures a new
maximum.
Press again to return to normal mode.
Operation
1. Refer to the Settings Table. Set the selector to the proper setting
and connect the test leads to the meter. Start with the highest
measurement range.
2. Refer to "Typical Measurements" for specific measurement
instructions.
3. Test the unit on a known functioning circuit or component.
• If the unit does not function as expected on a known functioning
circuit, replace the battery and/or fuses.
• If the unit still does not function as expected, send the unit to
Greenlee for repair. Refer to the instructions under the Warranty.
4. Take the reading from the circuit or component to be tested. If the
resolution is not satisfactory, remove the meter from the circuit
and change to the next lower range.
8
will appear on the display. The highest value will remain
Electric shock hazard:
Contact with live circuits could result in severe
injury or death.