MCS Master BCF 230RB Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
en
►►3. ASSEMBLY AND
INSTALLATION (ONLY FOR
QUALIFIED PERSONNEL)
NOTE: TO ACCESS THE INTERNAL
PARTS OF THE COOLER, REMOVE
THE SCREWS AND EVAPORATION
PANELS, REMOVE PANELS LOCATED
ON SIDES OF THE DEVICE (Pic. 2).
►3.1. HANDLING
Handle the cooler with the utmost care,
moving it horizontally.
►3.2. PRE-INSTALLATION AND
INSTALLATION METHOD
(Pic. 3):
During
installation,
connection, water connection, use and
maintenance of the cooler, comply with
all local regulations and standards in
force.
►3.2.1. The cooler must be installed
on a stable and level structure, so as to
prevent any risk (the structure and the
plugs must be adequate to support the
weight of the appliance).
►3.2.2. Install the cooler in well ventilated
areas.
►3.2.3. The cooler can only be installed
outside (on the roof or on the wall).
►3.2.4. Install the cooler away from
fireplaces, heat sources and possible
sparks, in order to prevent serious
damage.
►3.3. DUCTING METHOD
By connecting a conduit to the cooler,
the outgoing air can be carried to where
cooling is required.
It is crucial for the entire ducting conduit
to be designed and structured correctly.
Figures and texts of this book are protected by COPYRIGHT.
the
electrical
►3.3.1. Use conduits of suitable section
(the average air speed inside the conduit
is 3-6 m/s).
►3.3.2. The ducting should be as short
as possible.
►3.3.3. The pipes must be installed at a
maximum of 4 m above the ground.
►3.3.4. Do not install the duct with elbow
bends.
►3.3.5. The maximum length of the
conduit is 20 m.
►3.3.6. Up to four reductions can be
installed within the conduit.
►3.3.7. The pipe joints must be flexible.
►3.3.8. Do not branch the air flow into
several conduits.
NOTE:
WE
RECOMMEND
CONDUITS MADE OF GALVANISED
SHEET
METAL,
FIBREGLASS.
►3.4. CONNECTION TO THE
ELECTRICITY MAINS
IMPORTANT: THE POWER SUPPLY
AND
CONNECTION
BE INSTALLED BY A QUALIFIED
TECHNICIAN
USING
DEVICES AND INSTRUMENTS, IN
ACCORDANCE
REGULATIONS AND THE STANDARDS
IN FORCE.
►3.4.1. By removing the screws on the
side of the cooler you have access to the
interior of the appliance (Pic. 2).
►3.4.2. Feed the electrical cables
(power cable and the control panel cable)
through the hole near the electrical panel
(Pic. 4).
►3.4.3. Only connect and power the
cooler with the voltage and frequency
specified on the nameplate and with
cables of suitable section (observing the
phase-neutral polarity).
USING
PLASTIC
OR
LINE
MUST
SUITABLE
WITH
NATIONAL

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bcf 230abBcf 230alBcf 230au

Tabla de contenido