To guarantee a perfect combustion it's
•
necessary to preserve the wood in a dry
and clean place.
The wood thermic output is related to its
•
humidity in %. (see the schedule ).
2.3 Starting
The appliance should set at work only after having completed the following operations:
•
complete assembling, connection to exhaust fumes duct and to the heating plant. A new
appliance needs to complete the drying process of the paint. During the first heatings
you can notice the following situations:
- During the first ignitions the appliance may exhale bad smell. We suggest a good
aeration of the room till bad smells have been eliminated.
- The complete drying process will be obtained after some heating operations
The appliance is subject to expansion and contraction during use, it will emits small
•
crunches, which are absolutely normal and should not be considered a fault but a
characteristic of the device.
This appliance is a domestic stove with an integrated boiler fired by solid fuel, whose
•
functioning conforms to the standard EN 13240.
Thanks to combustion chamber structure, the equipment has an high calorific efficiency.
WOOD LOADING
The appliance should be loaded manually during the functioning.
•
The loading of combustible should be done when the flame is minimum to avoid
•
combustion products or fumes outlet from the fire door.
To open the fire door, employ the fixture enclosed.
•
Open the door of the fire box, put in the appropriate quantity of wood and close the door.
•
During this operation always use the tools furnished with the cooker.
STARTING AND FUNCTIONNING
N.B. For starting never use : alcohol, fuel, or others liquid combustibles.
In case of starting during particular cooling days or in a condition of low pressure, it's
•
advisable to heat the flue before the starting, burning inside it some pieces of papers.
After that effect a regular heating of the flue as well as of the appliance, introducing
small quantities of fuel, which allow an easy and rapid defluxion of the combustion
smokes
In case of starting during particular cooling days or in a condition of low pressure, it's
•
advisable to heat the flue before the starting, burning inside it some pieces of papers
For the combustible quantities please read the "Technical Data " .
•
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
ES mod. 696T-696TL-697FT-697FTL
GB
GB
FR
FR
ES
ES
38/92