User Manual
REMOVING THE GLASS DOME
1.
To remove the dome disconnect the flash cable from the power pack and leave the
head to cool down.
2.
Remove any accessories.
EN
3.
Turn the glass dome anticlockwise and pull. Please use gloves as a safety
precaution. Refit the glass dome by turning the dome clockwise until is locked.
FLASHTUBE REPLACEMENT
1.
Switch the power pack off.
2.
Disconnect the flash cable from the power pack.
3.
Place the head horizontally on a rigid, clean and dry surface.
4.
It will need to be held firmly whilst removing and replacing the flashtube.
5.
Allow the flashtube to cool down.
ALWAYS USE A PROTECTIVE GLOVE TO REMOVE THE FLASHTUBE!
6.
Remove the security spring from the flashtube and pull the flashtube firmly out of the
terminals.
7.
If the tube is broken, use security gloves to avoid cutting yourself and use an
insulated tool to pull out the electrodes. Never touch the metal electrodes.
8.
Now replace with a new correct original Elinchrom flashtube. An insulated tissue or
security gloves MUST BE USED. Any contact with your fingers on the tube, can cause
dark markings on the tube when used.
9.
Check that the tube is correctly aligned (central) and that the trigger contact is
gripping the tube with the security wire.
10.
Re-connect and test the head as usual.
NOTE: Check the correct polarisation when Action, A-type flashtubes are replaced! They
normally fit only in one direction!
6