Descargar Imprimir esta página

S&P EcoAIR DESIGN Manual De Instrucciones página 17

Ocultar thumbs Ver también para EcoAIR DESIGN:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
ATENTION: When the humidity rate is
above
the
selected
automatic option takes precedence
over the manual.
Settings
The manufacture settings are 60%HR for
humidity and 1 minute for timer.
The desired humidity level is selected by
means of a potentiometer "P3" positioned
on the printed circuit board (fig.8).
- To reduce the humidity setting turn
anticlockwise (min.60 %)
- To increas e the humidity setting turn
clockwise (max. 90 %)
To set he timer, turn the potentiome ter
"P2" on the printed circuit board (fig.8):
- To reduce the "run on" time, turn
anticlockwise (min. 1 minutes)
- To increase the "run on" time, turn
clockwise (max: 30 minutes).
Specific recommendations:
- If you change the settings of the
extractor fan you have to manipulate
he potentiometers in the printed circuit
board. These pots are fragile and must
be handled with care.
- Do not change the setting of the
humidistat out of he room where the
fan will be installed.
- If the humidity is always above 90%
RH, the fan will always run at full
speed.
- If the humidity in the room is always
less than 60%, the fan will only
operates at trickle speed when running
in automatic operation.
If the fan never runs at boost:
- The setting of the humidistat is to the
maximum. Change the setting
- The level of humidity in the room is
below 60% RH
value,
the
If the fan always runs at boost
- The setting of he humidistat is to the
minimum. Change the setting
- The level of humidity in the room is
above 90% RH
EcoAIR DESIGN M
EcoAIR DESIGN version similar to H
model, fitted with an internal pull cord
switch to operate the boost when the
humidity level is below the set point
(fig.6)
When switching off the internal pull cord
switch, the fan continues to operate at
boost the time set by the timer then runs
at trickle speed, unless the humidity level
exceeds the set point.
User instruction
This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and
understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made
by children without supervision.
Maintenance
The extractor fan only requires
periodical cleaning using a cloth lightly
impregnated with a soft detergent.
After Sales Service
We recommend you not to try to
dismantle or remove any other parts than
those mentioned as any tampering
would automatically cancel the S&P
guarantee. If you detect any fault,
contact your S&P dealer.
S&P reserves the right to alter specifications without
notice

Publicidad

loading

Este manual también es adecuado para:

Ct-17/18Kit ecoair design + ct-17/18