Continuity Test; Diode Test - LaserLiner MultiMeter-Compact Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7

Continuity test

To test continuity, turn the rotary switch
to position „Ω" and press the „Mode"
switch twice to activate the „Continuity
test" function. Then connect the
measuring contacts to the object to
be tested. A measured value of < 150
ohms is recognised as continuity; this
is confirmed by an audible signal. If
„O.L." appears on the display instead of
a measured value, either the measuring
range has been exceeded or the
measuring circuit is not closed or
has been interrupted.
8

Diode test

To test the diode, turn the rotary switch
to position „Ω" and press the „Mode"
button once to activate the „Diode test"
function. Then connect the measuring
contacts to the diode. The measured
value acquired for the forward voltage
appears on the display. If „O.L." appears
on the display instead of a measured
value, the diode has either been tested
in the reverse direction or is faulty. If
0.0 V is measured, the diode is faulty
or a short-circuit has occurred.
20
GB
Reverse direction
Black
Red
Forward direction
Forward direction
Red
Black

Publicidad

Tabla de contenido
loading

Tabla de contenido