12
Comparative measurement
The comparative measurement function takes a measurement
relative to a reference value that has been saved previously. This
enables the difference between the current measured value and
the saved reference value to be displayed. Press the „REL" button
whilst a reference measurement is being taken in the corresponding
measuring function. The display now shows the difference between
the current measurement and the set reference value. Press
the „REL" button again to deactivate the function. The „Rel"
function can only be used for voltage, current and capacitance
measurements, as well as continuity tests.
13
Hold function
The „Hold" function enables you to keep the current measured
value on the display. Press the „HOLD" button to activate and
deactivate the function.
14
LCD-Backlight
ON
2 sec
15
Voltage detection, non-contact (AC warning)
The non-contact voltage detector integrated in the meter is able to
detect AC voltages from 100 V to 600 V, thus enabling live cables
or cable breaks, for example, to be identified. Turn the rotary switch
to position „V" and run the voltage sensor along the object to be
tested (5 - 10 mm). The display lights up and the device starts to
vibrate if AC voltage is detected.
22
GB
OFF
2 sec