41017
ognition ID. The archive of a user's card-name pair-
ings is saved by SaveProg on the PC being used,
when programming the device.
In standalone mode, it is possible to configure input CA
and configure the activation time of relay F1.
In slave-2wire mode, input CA is enabled and relay F1
is configured directly on the AV module. Alternatively, in-
stead of controlling the output F1 of the device, recogni-
tion of a registered card may be used to control any other
output (relay/lock) of the audio or audio/video module or
other auxiliary modules of the external unit. You can also
configure the output F1 as a common or exclusive lock
for the external unit.
In the event of an error, the red LED will flash continuous-
ly. Check that: the device is connected to a compatible
audio or audio/video module; the wiring has been con-
nected correctly; the firmware versions of the modules
are updated.
3.2 Manual registration
The following manual registration procedure allows you
to add new user cards to the device without having to
use SaveProg:
• Hold a previously registered installer card up to the
reader;
• Within 5 seconds, hold the new card to be regis-
tered as a user up to the reader; the blue LED on
the device will flash rapidly during the registration
period;
• Hold the card in position until registration is con-
firmed; the green LED will illuminate for 1 second
(no command is activated);
• The procedure then restarts from step 2: the blue
LED starts flashing rapidly, indicating that another
user card can be registered within the next 5 sec-
onds.
If no card is read during the 5 second registration period,
or if there is a fault, the white LED will illuminate and the
procedure will be cancelled. Cards registered in this way
are given the name manual-n, where n is the incremental
number assigned to each new card registered. Cards can
only be deleted using SaveProg.
4. Eipvdes and slave-eipvdes modes
Refer to the documentation for Elvox IP and Video Door
IP Manager. These modes do not support the use of in-
staller cards.
5. Operation
When the device is in standby state, the white LED is
illuminated. When a user card is read, the green LED
illuminates for 3 seconds and the programmed command
is executed (activation of output F1 or other command
according to the configuration). If the card presented is
not registered, the red LED will flash for 3 seconds.
6. Updating
The device can be updated using SaveProg/FWUpdate.
Disconnect the device from the auxiliary power supply
and/or PoE, connect it to the PC by USB cable and start
the update procedure. During the update procedure, the
red LED stays on. If updating does not start within 30 sec-
onds of connecting the PC by USB cable, the device will
return to operating mode and it will no longer be possible
to update it. Disconnect and then reconnect the USB ca-
ble to repeat the operation.
When it is part of an Elvox IP video door entry system
(eipvdes or slave-eipvdes), the device is updated by via
Video Door IP Manager by the network.
NOTE: the device is able to operate in eipvdes and
slave-eipvdes modes and can be managed and updat-
ed using Video Door IP Manager if it is equipped with
firmware version 1.8.5.3 or later. If not, it can be updated
using SaveProg/FWUpdate.
EN
9