Fire Detection (must be enabled by your Installer)
This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning if
a fire condition is detected. Good fire detection depends on having adequate number of detectors placed in
appropriate locations. This equipment should be installed in accordance with NFPA 72 (N.F.P.A., Batterymarch
Park, Quincey MA 02269).
Testing
To ensure that your system continues to function as intended, you must test your system weekly. Please refer to the
"Testing your System" section in this manual. If your system does not function properly, call your installing
company for service.
Monitoring
This system is capable of transmitting alarms, troubles & emergency information to a central station. If you initiate
an alarm by mistake, immediately call the central station to prevent an unnecessary response.
NOTE: The monitoring function must be enabled by the installer before it becomes functional.
NOTE: There is a communicator delay of 30 seconds in this control panel. It can be removed, or it can be increased
up to 45 seconds, at the option of the end-user by consulting with the installer.
Maintenance
With normal use, the system requires minimum maintenance. Note the following points:
• Use the system test described in "Testing Your System" to check the battery condition. We recommend, however,
that the standby batteries be replaced every 3-5 years.
• For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave motion detectors or
glassbreak detectors, consult the manufacturer's literature for testing and maintenance instructions.
General System Operation
Your security system is made up of a DSC control panel, one or more keypads and various sensors and detectors.
The control panel will be mounted out of the way in a utility closet or in a basement. The control panel contains
system electronics and standby battery.
NOTE: Only the installer or service professional should have access to the control panel.
All the keypads have an audible indicator and command entry keys. The keypad is used to send commands to the
system and to display the current system status. The keypad(s) will be mounted in a convenient location inside the
protected premises close to the entry/exit door(s).
The security system has several zones of area protection and each of these zones will be connected to one or more
sensors (motion detectors, glass break detectors, door contacts, etc.). See Alarm Memory on page 7 for information
on sensors in alarm for this Touchscreen keypad.
Fire alarm verification is an available option on fire zones. When used, the system will begin an alarm transmission
sequence once the conditions for fire alarm verification are met. The fire alarm verification option is disabled by
default. Consult with your installer to enable fire alarm verification on your system.
A security system cannot prevent emergencies. It is only intended to alert you and, if included, your central station of
an emergency situation. Security systems are very reliable but they may not work under all conditions, and they are not
a substitute for prudent security practices or life and property insurance. Your security system should be installed and
serviced by qualified security professionals who should instruct you on the level of protection that has been provided
and on system operations.
The WTK5504* two-way wireless touchscreen keypad is an interactive touch-sensitive color LCD that can be used
with the Alexor PC9155 and Impassa SCW9055/57 wireless panels. It can also be used with the PowerSeries alarm
panels in conjunction with a TR5164 transceiver module. The WTK5504P model is compatible with proximity (prox)
tags, which can be used to arm, disarm, and enter user functions (Alexor PC9155 and Impassa SCW9055/57 only).
Due to the custom requirements of individual installations, some of the features described here may perform differ-
ently than described. Refer to your Installation Instructions for the details of your specific installation and to this User
Manual for general security system information.
Specifications/Features
• Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3" WQVGA (480
• LED indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 (Ready, Armed, Trouble, AC)
• "Night" light with adjustable brightness
• Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6" x 4" x 1.3" [152 mm (L) x 102 mm (W) x 33 mm (D)]
• Horizontal viewing angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140° (typ.)
• Vertical viewing angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70° (top), 50° (bottom) (typ.)
• Brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 cd/m
• Operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 49°C (32°F to 120°F)
• Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.92 MHz
• Relative humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93% non condensing (max.)
• Display language(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . English, French, Spanish, Portuguese
*The models covered by this manual are WTK5504P-433 and WTK5504-433. The reference to WTK5504 throughout
this manual is representative for both model names unless it is identified differently.
IMPORTANT NOTICE
Introduction
272 pixel) color resistive touchscreen
2
2