Electrical Connection To The Range; Direct Electrical Connection To The Circuit Breaker, Fuse Box Or Junction Box - Frigidaire FGES3065PF Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
5.
Electrical Connection to the
Range (U.S.A.)
Three Conductor Wire Connection to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 3):
1. Remove the screw holding the rear wire cover,
then remove the rear wire cover (access cover)
to expose range terminal connection block (see
Figure 2).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal) (see figure 3).
3. Put back the rear wire cover using the screw
removed on step 1.
Grounding
Strap
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
To 240 V
Location.
Receptacle
Figure 3
Four Conductor Wire Connection to Range
Where local codes DO NOT permit connection of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 4):
1. Remove the screw holding the rear wire cover,
then remove the rear wire cover (access cover)
to expose range terminal connection block (see
Figure 2).
2. Remove the grounding strap. Remove the screw
that holds the strap against the appliance. Cut the
strap off at the terminal block, or bend the strap
back and forth to break it from the terminal block.
Silver Colored Terminal
Red Wire
Cord
Mounting
Plate
Neutral
(White Wire)
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.
DO NOT loosen the screws that attach the terminal
block to the appliance.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance with
the ground screw, using the hole in the frame where
the ground strap was removed (see Figure 4).
4. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Put back the rear wire cover using the screw
removed on step 1.
Terminal Block
Black Wire
1 1/8" (2,9
cm) Dia.
Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8" (3,5
cm) Dia. Cord
Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
Disconnect power to the circuit breaker
or fuse box before making the electrical connection.
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 4) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (see Figure 5):
7
Silver Colored Terminal
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V
Receptacle
Figure 4
Red
Wire

Publicidad

Tabla de contenido
loading

Tabla de contenido