SATA 244 Instrucciones De Servicio página 50

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

<< Operating instructions SATA filter 244/264/284 >>
US
Information!
Activated charcoal filter cartridge:
• Fiber-bound activated charcoal
• Surface 300 cm²
9.4. Pressure regulation valve [D]:
The requested outlet pressure can be adjusted with the pressure adjust-
ment knob [1-5] at the pressure regulation valve [1-4]. The pressure is
displayed at the pressure gauge [1-3]. The pressure regulation valve se-
cures consistent outlet pressure.
9.5. Air outlet module [E]:
The outlet module is equipped with each 2 quick couplings and connec-
tion nipples G 1/4 i [1-6].
10. Maintenance
• Filters can only be maintained and serviced when depressurized!
• Sintered filter [A]/Art. No. 22160 and filter housings [1-8], [1-12]
have to be cleaned after 6 months at the latest; replace sintered filter,
if necessary!
• The fine filter cartridge [B]/Art. No. 81810 has to be replaced every
6 months at the latest!
• The activated charcoal cartridge [C]/Art. No. 85373 has to be re-
placed every 3 months at the latest!
• When the compressed air is heavily contaminated, the filter
cartridges have to be exchanged in shorter intervals!
• Saturated filter cartridges may cause quality problems during paint
jobs. Furthermore, using a supplied-air respirator could become harm-
ful, causing permanent health damage and even death!
• Depressurize filter (close shut-off tap)
• Unscrew [3] the respective filter housing with the pin spanner included
in the delivery.
• Remove condensate cyclone separator [4-1] from the filter stage
[A], remove and check insert as well as sintered filter [4-2]. Clean or
replace if necessary
VI.6
Danger! Notice!

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

264284

Tabla de contenido