Installation Site - Quick VRG 08 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CHARACTERISTICS AND INSTALLATION
GB
VRG SERIES VOLTAGE REDUCER
The long experience we have in the nautical field has given us the ability to develop the line of VRG voltage
reducer that guarantee higher performance when compared with other models currently on the market.
The advantages of the VRG voltage reducer are described below:
• Electric insulation between the input and output.
• Protection against shorts, overloads, output overvoltage, reverse polarity and overheating.
• Battery protection (prevents the battery from being excessively discharged).
• Low residual output fluctuation (ripple lower than 50 mV RMS).
• Complies with EN 12895.
INSTALLATION
BEFORE USING THE VOLTAGE REDUCER CAREFULLY READ THIS USER'S MANUAL. IN CASE OF DOUBT
CONTACT THE "Quick
THE VOLTAGE REDUCER HAS BEEN DESIGNED FOR FIXED INSTALLATIONS (FOR INDOOR
USE ONLY).
"Quick
" voltage reducer have been designed and made for the reasons described in this user's manual.
®
The "Quick
®
" Company does not accept any responsibility for direct or indirect damage caused by
improper use of the equipment, bad installation or by possible errors occurring in this manual.
THE OPENING OF THE VOLTAGE REDUCER BY UNAUTHORISED PERSONNEL MAKES THE
WARRANTY VOID.
THE PACKAGE CONTAINS: voltage reducer – warranty card – user's manual.
EQUIPMENT NEEDED FOR INSTALLATION
On the basis of the type of model, use the batteries, electrical terminals, and cables for the input/output
terminals and the output fuse as specified in the following table:
MODEL
Input battery voltage
Recommended battery capacity
Minimum output cable size
Output fuse
Electric terminals
The required cable size is to be calculated according to the length of the conductors in order to avoid
excessive voltage drops.

INSTALLATION SITE

Install the voltage reducer in a dry and ventilated place.
The voltage reducer, although having high efficiency, develops a certain amount of heat during function-
ing, therefore, it is imperative that the installation area has sufficient ventilation, enough to allow use of
the equipment at maximum power.
The voltage reducer can be installed in a horizontal or vertical position with cables coming out in the
downward position. The vertical position is recommended because the natural convection of heat helps
to cool the equipment.
8
" SUPPLIER OR AFTER SALES SERVICE DEPARTMENT.
®
VRG 08
>35 Ah
2
4 mm
12 A FAST
VRG 15
24 V
>60 Ah
2
6 mm
20 A FAST
FAST-ON FEMALE, 6.3 x 0.8 INSULATED
VRG 25
>100 Ah
2
10 mm
30 A FAST

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vrg 15 serieVrg 25 serie

Tabla de contenido