The perimeter of the voltage reducer (except the base) must be kept at a distance from walls or objects
by a minimum of 5 cm. The base that the voltage limiter is mounted on must be able to withstand a maxi-
mum temperature of 80°C (at an ambient temperature of 40°C).
WARNING: the outer surface of the voltage reducer is used as a heat sink, therefore it may reach
very high temperatures (risk of burns). Leave the equipment to cool down before handling it.
FIG. 1
5 cm

ELECTRICAL WIRING

The equipment is to be wired up as shown in figure 1. Join the insulated fast-on terminal to the output
terminals of the voltage reducer. Always check the input and output terminals for correct polarity.
The electrical wiring is to be done in compliance with local electrical codes.
WARNING: before connecting the batteries, always check the battery cables for correct polarity.
Remember that wrong polarity may seriously damage the voltage reducer even if the protected by
a fuse.
WARNING: before connecting or disconnecting the cables from the voltage limiter terminals,
make sure they are not live.
WARNING: the use of inadequate size cables and incorrect connection of terminals or electrical
joints may result in dangerous overheating of the connecting terminals or cables.
5 cm
5 cm
5 cm
INSTALLATION
EQUIPMENT
12 V
FUSE
TEST
OUT
ON
Green OK
13,5 Vdc
Red
BATTERY
24 V
IN
Error
POWER
VRG
XX
GB
9