Fault Correction; Replacement Parts - Franke AQRE 432 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

21. Fault Correction

Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water-volume too
much
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!

22. Replacement Parts

Designation
1 Cover plate . . . . . . . . . . . . . . . . . . 85-100-20.663
2 Controller . . . . . . . . . . . . . . . . . . . 85-100-20.588
3 Solenoid valve cartridge 24 V DC . 85-032-01.365
4 Mounting frame . . . . . . . . . . . . . . . 85-100-20.329
5 Transformer . . . . . . . . . . . . . . . . . 85-100-07.972
6 Flush-plugs/Fitting key . . . . . . . . . 85-017-02.077
7 Valve seat with O-ring . . . . . . . . . . 82-500-01.017
Cause
– Water supply interrupted
– Water flow regulator closed
– Voltage supply interrupted
– Solenoid valve faulty
– Sensor faulty
– Range incorrectly set
– Solenoid valve dirty
– Solenoid valve faulty
– Water volume regulator is not fully
opened
– Supply pressure too low
– Flush-volume adjustment is
incorrect
– Flush-volume adjustment is
incorrect
– Water-volume regulator opened too
far
Order No.
Designation
8 Maintenance kit comprising:
O-ring
Circlip . . . . . . . . . . . . . . . . . . . 82-500-03.019
Replacement kit for solenoid valve cartridge
Consisting of:
Rubber parts . . . . . . . . . . . . . . 82-500-01.031
Accessories
9 Remote control . . . . . . . . . . . . . . 5207 10 00
Remedy
➯ Restore it
➯ Open it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Clean it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it
➯ Close
Order No.