4.

Important Notes

• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
5526 11 24-F:
breaker (RCD).
• All rights reserved to make technical alterations.
5.

Application

Complete installation kit for PROTRONIC - non-touch, opto-electronically controlled
urinal flush-valve DN 15 for in-wall installation. Individual control unit in compact
design. Automatic forced flushing after 24 hours of non-use.
Optional: Function parameters adjustable by remote control.
5526 11 24-F ... with mains connection
5526 12 24-F ... for separate power supply
6.

Technical Specifications

Minimum flow pressure:
Recommended flow pressure:
Maximum operating pressure:
Calculation flow rate:
Flushing flow rate:
Flush water volume:
Flushing duration
Operating voltage:
5526 11 24-F
5526 12 24-F
Operating voltage:
Power consumption:
5526 11 24-F
5526 12 24-F
Type of protection:
Secure the electric connection with an earth leakage circuit
1.0 bar
1-4 bar
10 bar
0.30 l/s
0.3 – 0.7 l/s
2 – 4 l
0.6 – 6.5 s (adjustable in 6 steps)
230 V AC, 50/60 Hz
24 V DC
24 V DC
2.5 VA
3 W
IP 54
5