ENGLISH
Set required room temperature (fig.21)
Before proceeding with the steps indicated below, press the
ESC button to exit and return to the initial menu. The
preferred room temperature can be selected as follows:
- press and hold the SET button
- press the SET button briefly (the current value flashes)
- select the required value using the UP and DOWN buttons
- press the SET button briefly to retain the setting
- press the ESC button briefly to exit.
Activate "bypass" function (fig.22)
The purpose of the bypass function is to ventilate the
apartment without heat transfer. With the bypass valve open,
air can be introduced directly from outside, without passing
through the heat exchanger. The flow of air vented from
inside continues to pass through the heat exchanger. Before
proceeding with the steps indicated below, press the ESC
button to exit and return to the initial menu. The "bypass"
function can be forced by pressing and holding the ESC
button. The corresponding "money box" icon will light up (the
function remains active for 12 hours, after which the
appliance will revert to automatic operation)
View time/outdoor temperature display (NO UK or models with HA) (fig.23)
23
23
FILT
1
2
3
esc
Prg
/ °C
By-Pass
22
P1
P2
HA
4
5
6
7
set
21
21
FILT
1
2
3
esc
/ °C
By-Pass
22
22
FILT
1
2
esc
/ °C
By-Pass
Before proceeding with the steps indicated below, press the
ESC button to quit and return to the initial menu.
The current values of the "time" and "outdoor temperature"
parameters can be viewed in alternation by pressing the ESC
button briefly.