4
X
Measure overall length of configured system
with adapters attached.
Reduce this measurement enough to allow for
full engagement of the pipe into the adapters and
determine how much pipe to remove (X).
Mark section of pipe to be removed
6
BRASS COMPRESSION NUT
FERRULE
Slip brass compression nut and ferrule onto each
end of 1˝ pipe.
5
X
Using a pipe cutter or hacksaw, cut and remove
marked section of pipe. File or sand sharp edges
on remaining pipe.
7
Align filter assembly with ends of pipe, making
certain your water flow is in the same direction as
the arrows on your filter head. It will be necessary
to spread ends of pipe apart to install filter
assembly. Using two adjustable wrenches, hold
incoming fitting securely with one wrench and
tighten nut with second wrench. Repeat process
for outgoing fitting.
6
8
CAUTION: If water pipes are used to ground
electrical systems, appliances or phones, be
certain to install a jumper wire.
10 WH-HD100-O
Ensure the filter housing has been properly
tightened using the housing wrench provided.
Slowly turn on main water supply.
Slowly press red pressure-relief button on top
of filter to release trapped air. Check for leaks.
Open nearest faucet and flush filter cartridge
for 5 minutes.
9
If using optional mounting bracket attach
it to the wall using four mounting screws
(not included).
10
WH-HD200-C
Ensure the filter housing has been properly
tightened using the housing wrench provided.
Turn bypass valve to "Filter" mode using wrench,
then slowly turn on main water supply.
Slowly press red pressure-relief button on top
of filter to release trapped air. Check for leaks.
Open nearest faucet and flush filter cartridge
for 5 minutes.
Reset filter life indicator (hold reset button
for 2 seconds).