Electrical Connection; Conversion Of Gas Supply - Angelo Po 090FT1G Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ELECTRICAL CONNECTION

Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
230V/1N.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
A

CONVERSION OF GAS SUPPLY

The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 24).
3 - Change the pilot light nozzle (see page 24).
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual. Use a cable with at
least H05RN-F characteristics.
Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.
5 - Replace the control panel (D) and the knobs (B)
on completion of the operation.
B
C
C
D
A
- 21 -
E
IT
GB
IDM-39614701201.tif
DE
FR
ES
IDM-39603309600.tif
English

Publicidad

Tabla de contenido
loading

Tabla de contenido