Electrical Connection - Angelo Po 0N0GRG Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Important
The equipment comes with a cable to con-
nect it to the outlet of the disconnecting
switch. If it is necessary to change the cable,
proceed as described below.
Important
The connection must be made by authorised,
skilled personnel, in accordance with the rele-
vant legal requirements, using appropriate and
specifi ed materials. The appliance is supplied
with operating voltage 230V1~N 50 Hz.
For direct connection to the mains one must en-
visage a device that ensures disconnection from
the mains, with a contacts opening distance
that ensures complete disconnection in the con-
ditions of category III over-tension, in complian-
ce with the installation rules.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
GB
B
D
3320070_inst_GB_rev.1

ELECTRICAL CONNECTION

C
E
C
If not already present, install an automatic
1)
circuit-breaker
(A)
the following characteristics:
– Thermal breaker device ( to adjust see table
Annexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at 30 mA.
Pull off the knob (B).
2)
Take out the screws (C) and take down the
3)
dashboard (D) to access the electric box (E).
Undo the screw (F) to remove the lid (G).
4)
Connect the circuit-breaker (A) to the terminal
5)
board (H) as shown in the diagram and in the
electrical system diagram at the back of the
manual and using a cable with the following:
– Weight: ≥ than H05RN-F type (designation 245
IEC 57).
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Replace all when the operation is complete.
6)