Vortice 60-I Manual De Instrucciones página 3

Ocultar thumbs Ver también para 60-I:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
replaced. To restart the hour counter (RESET), hold the button A pressed down for about 1" (while the pilot lamp
S is on). Button B: drives the motor in first speed (the corresponding pilot lamp comes on); when holding it down
for about 1", the motor cuts out; when pressing the button a second time (while the pilot lamp is on) , the TIMER
is activated and thus the motor stops after 5' (the pilot lamp flashes). Button C: drives the motor in second speed
(the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) ,
the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Button D: drives the motor in
third speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp
is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Button E: drives the
motor in fourth speed (the corresponding pilot lamp comes on); when pressing the button a second time (while
the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes).
Pay special attention to the grease filters; to remove the filter: push inward on the clamp at the handle and
pull the filter downward. Wash out the filter using a neutral soap. if the model purchased has the controls shown
in Figure 13: see the paragraph "Controls shown in Fig. 13" ("Filter Alarm"). If the model purchased has the controls
shown in Figure 11/12: the grease filter must be cleaned periodically: exactly how often depends on use (at least
once every other month). If the model purchased has the controls shown in Figure 14: the grease filters must
be cleaned approximately once every 30 hours of operation (when the light button lamp comes on) - Fig. 14S).
Once the cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1"
(Fig.14A) while the corresponding pilot lamp (S) is on. For further information, see the Controls in Fig.14 in the
paragraph entitled "Operation".
Charcoal filter/s: if using the hood in the filtering hood, the charcoal filter must be replaced periodically. To
remove the charcoal filters, proceed as follows, depending on the model purchased:
- if the hood features round charcoal filters (Fig. 15), remove the charcoal filter by turning clockwise.
- if the hood features a panel type charcoal filter (Fig. 10), remove the charcoal filter by first of all removing the
two filter retainers M.
If the model purchased has the controls shown in Figure 13, see the paragraph "Controls shown in Fig. 13" ("Filter
Alarm"). If the model purchased has the controls shown in Figure 11/12, the charcoal filters must be replaced
according to use: on the average once every 6 months. If the model purchased has the controls shown in Figure14,
the charcoal filters must be replaced each time the light button (Fig.14S) lamp flashes (i.e. every 120 hours of
operation).
Lighting:
- To gain access to the lamps, remove the grease filters as described above and remove the bulbs. Replace
with lamps of the same type (Fig.16).
ENVIRONMENTALLYCOMPATIBLE DISPOSAL OF THE APPLIANCE
In certain european union countries this product does not fall within the requirements of the nationallaws
implementing the Weee directive, and in these countries the product is not subject to separatedisposal
operations at the end of its working life.
Important
This product conforms to EU Directive 2002/96/EC.
This appliance bears the symbol of the barred waste bin. This indicates that, at the end of
its useful life, it must not be disposed of as domestic waste, but must be taken to a collection
centre for waste electrical and electronic equipment, or returned to a retailer on purchase
of a replacement.It is the user's responsibility to dispose of this appliance through the
appropriate channels at the end of its useful life.
Failure to do so may incur the penalties established by laws governing waste disposal. Proper differential collection,
and the subsequent recycling, processing and environmentally compatible disposal of waste equipment avoids
unnecessary damage to the environment and possible related health risks, and also promotes recycling of the materials
used in the appliance. For further information on waste collection and disposal, contact your local waste disposal service,
or the shop from which you purchased theappliance. Manufacturers and importers fulfil their responsibilities for recycling,
processing and environmentally compatible disposal either directly or by participating in collective systems.
DEUTSCH
GERÄTEAUSFÜHRUNG
Das Gerät kann in Umluftversion und in Abluftversion geliefert werden. In der Umluftversion (Abb. 1) werden
die durch das Gerät geleitete Luft und der Dampf durch Kohlefilter gereinigt und dann über die seitlichen
Lüftungsgitter der Haube wieder in Zirkulation gebracht. ACHTUNG: Bei Verwendung der Umluftversion sind ein
Kohlefilter und ein Luftableitblech (A) notwendig, das in den unteren Teil des Rohrs eingebaut wird und ein erneutes
Einleiten der Abluft in den Raum ermöglicht. Die Kohlefilter werden nicht mitgeliefert. In der Abluftversion (Abb.2)
werden die Dämpfe und Küchengerüche direkt über eine Evakuationsöfffnung in der Wand oder Decke nach außen
IMPORTANT INFORMATION CONCERNING THE

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

90-i

Tabla de contenido