Replacing The Plastic Hose; Replacing The O-Ring For The Isolating Valve; Fault Correction - Franke AQUALINE Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18

16. Replacing the Plastic Hose

16.1 Remove the cover plate (see
16.2 Press in the rings (a) in the arrow direction and pull out the plastic hoses (b).
16.3 Reassemble in the reverse order.

17. Replacing the O-ring for the Isolating Valve

17.1 Interrupt the water supply.
17.2 Remove the cover plate (see
17.3 Remove the circlip (a) with the appropriate pliers for inner circlips.
17.4 Use a screwdriver to unscrew the closing unit (b).
17.5 Replace the O-ring (c).
17.6 Reassemble in the reverse order.

18. Fault Correction

Fault
Water does not flow
Water flows
continuously
Flow duration too
short or too long
Water flow too weak
Water flow too much
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
8
Chapter
14.).
Chapter
14.).
Cause
– The closing unit or the water volume
regulator are closed
– Pushbutton activation faulty
– Self-closing cartridge element
defective
– Self-closing cartridge element
defective
– Valve seat defective
– Pushbutton activation faulty
– Flushing volume adjustment incorrect
– Self-closing cartridge element
defective
– Closing unit or flow volume regulator
are not fully opened
– Supply pressure too low
– Flushing volume adjustment incorrect
– Flushing volume adjustment incorrect
– Flush-flow adjustments incorrect
Remedy
➯ Open it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it
➯ Adjust them