Resetting the AW12.
When leaving the factory, the AW12 is set to the default address A1 en does not respond to
the optional functions All Lights On/All Lights Off/All Units Off.
If the address and settings for the options "All lights on/All lights off /All Units Off" aren't
known, the default address of A1 can be set by applying power to the unit and sending the
address P16 to the unit twice (using any X-10 controller - i.e.: TM13 + RF remote control).
This can either be just the address "P16" or "P16 On" or "P16 Off". The commands must be
sent within 30 seconds of applying power to the unit.
Setting the default address automatically cancels the options "All Lights On", "All Lights Off"
or "All Units Off".
Exiting the programming mode.
Automatic: Wait for 1 minute. The device will then automatically exit the program mode.
Manually: To return to Run Mode: either send "Address On", "Address Off" or press the key
quickly (no more than 1. 5 seconds between key presses). After 5 key presses or "On/Off"
commands, the relay will start to respond, indicating that the unit is back in Run Mode.
Detailed information on the type of switch.
All switches must be connected to the live wire. If a momentary switch is used, the relay changes
state each time the key is pressed, as long as the key press lasts for less than 1.5 seconds.
If a standard wall switch is used , it is assumed the key press will last for more than 1.5
seconds. In this case the relay changes state on both the closure and release.
This type of response will allow the unit to also perform 2-way control if 2 switches are
connected in series - as would be the case with 2-way switching.
FAQ.
What is the reason for modules to switch on/off spontaneously?
It is possible that a Marmitek X-10 System is installed at one of your neighbours using the
same House Code. To solve this problem try to change the House Code of your system, or
have FD10 Phase Coupler/Filter installed at your incoming mains.
My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House
Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek Security Console installed in your house. These components will translate the radio
signals to the Marmitek X-10 signal on the power line. Only one Transceiver should be
installed for all remotes and sensors set to the same House Code.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your
remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to
AW12
TM
7

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lm15b

Tabla de contenido