INTENDED USE
The Wap turbo D can be
used for all cleaning
operations in commerce,
crafts and industry.
Thanks to its wide range
of accessories, it can be
used for a large number
of applications.
The machine can be
classified and used as an
industrial vacuum cleaner
to utilization category "C"
when employed in
accordance with its
intended use for picking
up non-flammable, dry
dusts with TLV ratings and
carcinogenic substances
from groups II and III (see
Hazardous Substances
Regulations, Annex II, No.
1.1.1).
Utilization category "C"
includes:
Utilization category "U":
Suitable for removal of
dusts with TLV ratings > 1
3
mg/m
Utilization category "S":
Suitable for removal of
dusts with TLV ratings >
3
0.1 mg/m
.
Utilization category "G":
Suitable for removal of
dusts with TLV ratings.
TL TL TL TL TLV V V V V rating: (extract from
the TLV rating list)
TL TL TL TL TLV V V V V rating (T T T T T hreshold
L L L L L imit V V V V V alue) is the
maximum admissible
8
concentration of a
substance as gas, vapour
or particulate in the air at
the place of work which
generally does not impair
the health of the
employees and does not
disturb the employees to
any considerable extent.
NOTE
The WAP turbo D is also
suitable for picking up
non-flammable liquids.
DESCRIPTION OF THE
MACHINE
•
Sturdy, powder-coated
chassis, large wheels,
steering rollers with
parking brake and
large-volume stainless
steel container.
•
Turbine suction unit
with poly-V flat-belt
drive, motor and
mounting plate.
Combination with
baseplate of cast
aluminium and belt
tensioning device via
eccentric.
•
Absolute filter
cartridges for removal
of dust, water-damp
or dry.
•
2-layer bag-type safety
filter with disposal
sleeve for dust-free
disposal.
•
Possibility of using 2-
layer bag-type filter for
disposal of dusts with
TLV ratings > 1 mg/m
(Art. No. 14912).
•
Possibility of using
* = measured with test aerosol 3 (DIN 24 184)
Wap micro-filter
cartridge, 3-layer for
particulates, germ-
contaminated dusts
(Art. No.
11617).
TESTS AND APPROVALS
The filter material of the
Wap absolute filter
cartridges has been tested
by the BIA in accordance
with ZH 1/487 para. 2 and
has a mean permeability <
0.07%* measured at an
air flow velocity of 0.05
m/s (corresponding to a
specific filter surface load
of 180 m
3
/(m
2
The 3-layer filter
combination of the Wap
micro-filter cartridges has
been tested by the BIA in
accordance with ZH 1/487
para. 2 and has a mean
permeability < 0.01%*
measured at an air flow
velocity of 0.05 m/s
(corresponding to a
specific filter surface load
3
2
of 180 m
/(m
The two-layer filter
material of the bag-type
safety filter has been
tested by the BIA in
accordance with ZH 1/487
para. 2 and has a mean
permeability of <
0.042%* measured at an
air flow velocity of 0.056
m/s (corresponding to a
3
.
specific filter surface load
3
2
of 200 m
/(m
x h)).
x h)).
x h)).