baltur LC3 Manual De Instrucciones página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
FOR MODULATING TBG 45 - 60
fig. 2
Anchor the regulator (A) to the plate (D) using the screws (E)
provided with the regulator. Place the seal (B) between the
regulator and the plate.
After wiring the cable (I) to the 4-pole connector (M) supplied
with the burner, connect cables (I), (L) and (S) on the modulation
probe to the regulator's terminal board as shown in the attached
wiring diagram.
Place the regulator into the case (G), then fix the plate (D)
in place with the screws (C) provided and tighten the cable
glands (H).
After removing the protective cover, take the two caps shown in
figure 2 off the electrical panel support and pierce the film on the
housing for the cable gland (R) supplied with the kit.
Fix the bracket (N) and then the case (G) in place using the 4
screws (P) (figures 2 and 3).
For the versions with pneumatic control, connect the 4-pole
connector (M) to the corresponding socket and the three wires of
the cable (L) to the terminal board in the printed circuit as shown
in figure 3. To ensure proper wiring, refer to the wiring diagram
supplied with the burner. Lastly, tighten the cable gland (R).
11 / 16
0006160005_201502
fig. 3
For the versions with mechanic cam, connect the 4-pole
connector (M) and the three wires of the cable (L) to the device
terminal board as shown in figure 4. To ensure proper wiring,
refer to the wiring diagram supplied with the burner. Lastly,
tighten the cable gland (R).
fig. 4

Hide quick links:

Publicidad

Tabla de contenido
loading

Productos relacionados para baltur LC3

Tabla de contenido