Troubleshooting Service Faults - Westen quasar E 24 F Manual Para El Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
Description of
Parameter
parameters
F19
Factory
setting
F20
Factory
setting
F21
Factory
setting
F22
Factory
setting
F23
Factory
setting
F24
Factory
setting
F25
Factory
setting
F26
Factory
setting
F27
Factory
setting
F28
Factory
setting
F29
Factory
setting
F30
Factory
setting
F31
Factory
setting
F32
Factory
setting
F33 - F34
Factory
setting
F35
Factory
setting
F36
Factory
setting
F37
Factory
setting
F38
Factory
setting
F39
Factory
setting
F40
Factory
setting
F41
Factory
setting
F42
Factory
setting
F43
Factory
setting

15. TROUBLESHOOTING SERVICE FAULTS

The faults shown on the display are identified with the symbol "E" and a number (fault code). For a
complete list of faults, see the following table.
If "R" appears on the display the fault must be RESET by the user.
To reset, press and hold down
Centre.
CODE
FAULT
DISPLAYED
E01
Shut down for ignition
failure.
E02
Shut down by safety
thermostat.
E03
Board configuration error.
E04
Safety error due to
ignition failure or frequent
flame loss.
Factory settings
24 F - 18 F
001
000
030
110
010
005
000
165
010
070
020
000
180
170
004
015
020
003
000
067
120
010
042
001
for at least 2 seconds. If this fault persists, call the Authorised Service
POSSIBLE REASON
• No inlet gas pressure.
• Ignition switch-flame sensor wire
interrupted.
• Flame sensing electrode faulty or
incorrectly positioned.
• Gas valve faulty.
• Electronic board faulty.
• No water in the primary circuit
(pump blocked or exchanger
obstructed).
• Limit thermostat faulty.
• Limit thermostat wiring
interrupted.
• CH flow NTC probe faulty.
• Electronic board faulty.
• Parameter F43 has not been set
correctly.
• See the reasons indicated in E01.
• See the reasons indicated in E42.
Parameter
Description of
parameters
F44
Factory
F45
Factory
F46
Factory
F47
Factory
F48
Factory
F49
Factory
F50
Factory
F51
Factory
F52
Factory
F53
Factory
F54
Factory
F55
Factory
F56
Factory
F57
Factory
F58
Factory
F59
Factory
F60
Factory
F61
Factory
F62
Factory
F63
Factory
F64
Factory
• Check that the gas valve is open and there is no air in
the gas supply circuit.
• Check the gas supply pressure.
• Check the wire is uninterrupted and makes good
contact with the flame sensing electrode and the
ignition switch.
• Check the connections between the gas valve and the
electronic board.
• Check the flame sensing electrode is in good
condition and in the right position (see the
POSITIONING THE IGNITION AND FLAME-
SENSING ELECTRODE section).
• Check pump operation (unscrew the front cap and
release the pump impeller with a screwdriver).
• Check the pump power input wiring.
• Check that the limit thermostat is undamaged and
replace it if necessary.
• Check the continuity of the limit thermostat wiring.
• Check the CH flow NTC probe (*).
• Check whether the exchanger is clogged.
• Set parameter F43 with the value indicated in the
table in the SETTING PARAMETERS section.
• See the actions indicated in E01.
• See the actions indicated in E42.
35
Factory settings
24 F - 18 F
setting
000
(this value depends on
setting
valve calibration)
setting
015
setting
007
(this value depends on
setting
valve calibration)
setting
105
setting
100
setting
005
setting
020
setting
100
setting
000
setting
003
setting
025
setting
000
setting
025
setting
005
setting
120
setting
015
setting
030
setting
025
setting
000
SERVICE ACTION