Descargar Imprimir esta página

Bpt HET/301 VR Manual De Instrucciones página 3

Publicidad

telephone-type single twisted pair
line.
An additional three video-entry or
audio-only entry panels can be
added to the first in series without
the need for other equipment
(selectors, distributors).
The entry panel comes complete
with:
- phonic unit;
- infrared LED for lighting the tar-
get area;
- three potentiometers for the fol-
lowing functions (fig. 3-4):
volume control at entry panel;
volume control at receivers;
P1 timed (in the range 1 to 15 s)
solenoid door-lock release.
The entry panel comes with system
busy and door-lock release buzzer.
The wires supplied make it simple
to connect the entry panel's
various component units.
Function of each terminal
Terminal block M1
14÷18V DC
power supply
solenoid lock output
door-lock release button
earth for solenoid lock
auxiliary command 1 out-
put
auxiliary command 2 out-
put
entry panel enabling out-
put
bus input from other entry
B IN
panels
bus output towards recei-
B OUT
vers or other entry panels
Terminal block M2
3
video signal
4
video signal earth
Connector functions
5-pin CN1 connector: used for con-
nection to VZS/308C in the entry
panel HEP/306 VR.
3-pin CN3 connector: used for con-
nection to buttons of HET/302÷304
VR entry panel.
1-red: to button n° 2.
2-orange: to button n° 3.
3-yellow: to button n° 4.
WARNING. In installations with a
number of entry panels, call but-
tons must be arranged in the same
order on each.
Connector CN4: comes ready con-
nected.
1-black: to button no. 1.
2-brown: to button no. 1.
3-green: to LEDs lighting the but-
tons.
4-yellow: to LEDs lighting the but-
tons.
WARNING. Wires belonging to
cables that are not used must be
insulated.
Function of jumpers SW1 and
SW2 (fig. 4)
SW1: automatic programming of
number of entry panels (default
setting 1).
SW2: programming of receivers.
Programming of number of entry
panels (only required where there
is more than one entry panel)
1 - Start with the last entry panel
connected in series to the bus
(usually the one with terminals B IN
not connected).
2 - Remove jumper SW1.
3 - Wait for the note confirming the
operation (approximately 3÷15 s).
The number of confirmation signals
also indicates the number of pre-
sent
and
programmed
panels (1 signal for the main entry
panel and 1 signal for each secon-
dary entry panel).
4 - Refit jumper SW1.
Programming receivers
1 - Remove jumper SW2 from any
entry panel.
2 - Lift the handset of the receiver
to be programmed.
3 - Press the door-lock release and
auxiliary 2 buttons at the same time
for at least 1 s (when audio towards
the entry panel is enabled, the
operation is confirmed).
4 - On the entry panel, press the
call button the receiver is to be
associated with.
5 - Replace the handset.
6 - Repeat the operation from point
2 on for all remaining receivers.
7 - Refit jumper SW2 to exit pro-
gramming.
WARNING. The programming
procedure for the VSE/300 selec-
tor, where fitted, must only be
performed once you have pro-
grammed which calls from the
entry panels are to be associated
with which receivers.
In installations with XA/300LR
we recommend you gather up
the receiver's ID (SN) codes,
applied on the outside of the
housing, and enter them in the
tables
that
come
with
XA/300LR,
MPP/300LR
IPC/300LR.
NOTE. Once the power supplier
has been programmed using a
PCS/300 or MPP/300LR unit, it
will no longer be possible to gain
access to the entry panel stan-
dard programming.
To restore default conditions,
please refer to the related chap-
ter.
Return to default conditions
from entry panel
1 - Remove the SW1 jumper.
2 - Close the earthed door open
contact.
A sound signal confirms that the
operation has occurred.
3 - Replace the SW1 jumper.
Technical features
• Power supply:
14÷18 V DC.
• Current demand:
- on stand-by with 14 V DC max.
120 mA;
- operating with 14 V DC max. 240
mA;
- with door-lock release activated,
add 500 mA;
- for each HEP/306 VR, add 35
mA;
- for each VZS/308C, add 15 mA;
- for each XDV/304A connected,
add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of
video signal.
• Door-lock release command:
pulse-type for solenoid lock at 12
V 1 A.
• Installation activation time: 60 s.
entry
• Call duration time: 30 s.
• Timed solenoid door-lock relea-
se: adjustable in the range 1 to
15 s.
• Bus output: power supply at 15 V
DC for booster and receivers
video driver balanced type (Z =
100 Ω).
• Aux 1 command output: 3.5 V
DC at 1mA (available only with
entry panel enabled, activation
time same as timed solenoid
door-lock release).
• Aux 2 command output: 3.5 V
DC at 1 mA (always available in
all entry panels, activation time
same as timed solenoid door-
lock release).
• Entry panel activation output: 3.5
V DC at 1 mA (enabled for entire
duration of conversation).
• Working temperature range: -15
°C to +50 °C.
Installation instructions
The embedding box must be fitted
flush with the wall at an appropria-
te height.
Fit the spacer into embedding
boxes to avoid deformation (fig.
1A).
WARNING. Connecting
must be fed through one of the
knockout cable entry points, loca-
ted at the bottom of the embedding
box (C in fig. 1).
The name card can be removed
and filled in with the relevant infor-
the
mation by removing the card clip
and
followed by the actual card itself
(fig. 2).
NOTE. Personalized name cards
can be used up to a maximum of 2
mm thick.
Secure the chassis to the front
plate using the two screws sup-
plied (fig. 3).
In order to fit the front plate on the
embedding box, screw on the two
fastening screws using the screw-
driver supplied (fig. 5).
DISPOSAL
Do not litter the environment with
packing material: make sure it is
disposed of according to the regu-
lations in force in the country where
the product is used.
When the equipment reaches the
end of its life cycle, take measures
to ensure it is not discarded in the
environment.
The equipment must be disposed
of in compliance with the regula-
tions in force, recycling its compo-
nent parts wherever possible.
Components that qualify as recy-
clable waste feature the relevant
symbol and the material's abbrevi-
ation.
INSTALLATIONS-
D
ANLEITUNG
AUSSENSTATION FÜR
VIDEOSPRECHANLAGEN
HET/301÷304 VR
Die Außenstation für Videosprech-
anlagen ermöglicht die komplette
Anlagensteuerung.
Für die Anlagen geeignet, die den
Einbau einer von der Außenstation
getrennten Kamera vorsehen.
Durch die Kombination mit den
Ruftastentableaus HEP/306 VR
können Anlagen mit bis zu maxi-
mal 64 Stromabnehmern geschaf-
fen werden.
Die Außenstation benutzt für den
Anschluss der Innensprechstellen
den Bus BPT X2 TECHNOLOGY,
der in einer einzigen verdrillten
Telefonschleife alle für den Anla-
genbetrieb erforderlichen Signale
überträgt.
Über die Serienschaltung an die
erste Außenstation ist das Hinzu-
fügen drei weiterer Außenstationen
sowohl für Videosprech- als auch
Haussprechanlagen
Benutzung weiterer Geräte (Wähl-
schalter, Verteiler) möglich.
Die Außenstation ist folgenderwei-
se ausgestattet:
- Lautsprecher- und Mikrofonsatz;
- LED mit Infrarotlicht für die
Beleuchtung des Subjekts;
- drei Spannungsteiler für die fol-
cables
genden Funktionen (Abb. 3-4):
Regelung der Lautstärke an der
Außenstation;
Regelung der Lautstärke an der
Innensprechstelle;
P1 Regelung (von 1 bis 15 s) der
Aktivierungsdauer des Elektrosch-
losses.
Die Außenstation ist mit einem
Tonsignal, der den Besetztzustand
der Anlage meldet, und mit einem
aktiven Elektroschloss ausgestat-
tet.
Die mitgelieferten Kabel sorgen für
einen leichten Anschluss an die
verschiedenen Geräte der Außen-
station.
Funktion der Klemmleisten
Klemmleiste M1
14÷18V DC
Stromversorgung
Ausgang Elektroschloss
Türöffnertaste
Masse für Elektroschloss
Ausgang Zusatzsteuerung
1
Ausgang Zusatzsteuerung
2
Ausgang Einschaltung der
Außenstation
Buseingang von anderen
B IN
Außenstationen
Busausgang
B OUT
Innen-sprechstellen oder
anderen Außenstationen
ohne
die
zu
den
3

Publicidad

loading

Este manual también es adecuado para:

Het/304 vr