Joannes CIPREA 24 D AS Instrucciones De Uso, Instalación Y Mantenimiento página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CIPREA D AS
Pressure adjustment at the burner
Since this unit has flame modulation, there are two fixed pressure settings: minimum and
maximum, which must be those given in the technical data table according to the type of gas.
Connect a suitable pressure gauge to the pressure point "B" downstream of the
gas valve.
Activate the TEST mode (see cap. 4.1).
Press the Eco/Comfort button for 2 seconds to access the gas valve Calibration
mode.
The card goes to the setting "q02"; displaying the actually saved value, by pressing
the DHW buttons .
If the pressure gauge reading is different from the nominal maximum pressure, pro-
ceed by increases/decreases of 1 or 2 units of parameter "q02" by pressing the
DHW buttons : the value is stored after each modification; wait 10 seconds for the
pressure to stabilise.
Press the heating button "-" (ref. 3 - fig. 1).
The card goes to the setting "q01"; displaying the actually saved value, by pressing
the DHW buttons .
If the pressure gauge reading is different from the nominal minimum pressure, pro-
ceed by increases/decreases of 1 or 2 units of parameter "q01" by pressing the
DHW buttons : the value is stored after each modification; wait 10 seconds for the
pressure to stabilise.
Recheck both adjustments by pressing the heating buttons and adjust them if nec-
essary by repeating the above procedure.
Press the Eco/Comfort button for 2 seconds to return to the TEST mode.
Deactivate the TEST mode (see cap. 4.1).
Disconnect the pressure gauge.
A - Upstream pressure point
B - Downstream pressure point
R
I - Gas valve electrical connection
R - Gas outlet
B
S - Gas inlet
I
A
TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A
S
fig. 15 - Gas valve
Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the
heating buttons detail 3 - fig. 1 to increase or decrease the power (min. = 00 - max. =
100). Press the reset button within 5 seconds and the max. power will remain that just
set. Exit TEST mode (see sec. 4.1).
Configuration Menu
Press the DHW buttons together for 10 seconds to access the configuration Menu. 7 pa-
rameters indicated by the letter "b" are available: which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Contents Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal instantaneous
2=Monothermal instantaneous
b02
Boiler type selection
3=Heating only (3-way valve )
4=Heating only (circulating pump)
0=Sealed Chamber combustion
control
(without fume pressure switch)
1=Open Chamber (with fume ther-
mostat)
Combustion chamber type
b03
2=Sealed Chamber (with fume
selection
pressure switch)
3=Sealed Chamber combustion
control
(with fume thermostat on recuper-
ator)
~ 24Ω
fig. 16 - Gas valve connection
Default
0=Natural Gas
0=Natural Gas
1=Bithermal instan-
1=Bithermal instan-
taneous
taneous
0=Sealed Chamber
0=Sealed Chamber
with
with
combustion control
combustion control
cod. 3541A371 - 07/2011 (Rev. 00)
Contents Description
Primary Exchanger type
selection
(b03=0)
No effect on adjustment
(b03=1)
b04
No effect on adjustment
(b03=2)
Primary Exchanger type
selection
(b03=3)
Operation selection
Relay card LC32 (b02=1)
No effect on adjustment
b05
(b02=2)
No effect on adjustment
(b02=3)
No effect on adjustment
(b02=4)
b06
Mains Voltage Frequency
Comfort burner on time
(b02=1)
No effect on adjustment
(b02=2)
b07
No effect on adjustment
(b02=3)
No effect on adjustment
(b02=4)
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
Service menu
~ 65Ω
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub-
menus are available: press the Heating buttons to select, in increasing or decreasing or-
der, "tS", "In", "Hi" or "rE". tS" means Transparent Parameters Menu, "In" Information
Menu, "Hi" History Menu: after selecting the submenu, press the Reset button again to
access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
16 parameters indicated by the letter "P" are available: which are also modifiable from
Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Contents Description
P01
Ignition ramp Offset
P02
Heating ramp
P03
Heating standby time
P04
Heating Post-Circulation
P05
Max. heating temperature
P06
Max. heating power
Burner shutdown in hot water production
(b02=1)
P07
Burner shutdown in hot water production
(b02=2)
Hot water tank hysteresis (b02=3)
Hot water tank hysteresis (b02=4)
CIPREA D AS
DHW standby time (b02=1)
DHW standby time (b02=2)
P08
DHW standby time (b02=3)
DHW standby time (b02=4)
DHW user max. set point (b02=1)
DHW user max. set point (b02=2)
P09
DHW user max. set point (b02=3)
DHW user max. set point (b02=4)
Anti-inertia function temperature (b02=1) 70-85°C
No effect on adjustment (b02=2)
Delivery temperature in hot water produc-
P10
tion (b02=3)
Delivery temperature in hot water produc-
tion (b02=4)
Range
Default
0=Flat
1=Omega
0=Flat
2=--
--
0
--
0
0=Flat
1=Omega
0=Flat
2=--
0=External gas valve
0=External gas
1=System filling solenoid valve
valve
2=Solar 3-way
--
0
--
0
--
0
0=50Hz
0=50Hz
1=60Hz
0-20 seconds
5 seconds
--
5
--
5
--
5
Range
Default
0-40
10
1-20°C/minute
5°C/minute
0-10 minutes
2 minutes
0-20 minutes
6 minutes
31-85°C
85°C
0-100%
100%
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
3=Solar (10)
4=Solar (20)
0=Fixed
1=Linked to set point
2=Solar (5)
0=Fixed
3=Solar (10)
4=Solar (20)
0-4°C
2°C
0-4°C
2°C
0-60 seconds
30 seconds
0-60 seconds
60 seconds
0-60 seconds
30 seconds
0-60 seconds
30 seconds
50-65°C
50°C
50-65°C
55°C
50-65°C
65°C
50-65°C
65°C
70°C
--
0
70-85°C
80°C
70-85°C
80°C
EN
CIPREA D AS
0=Flat
0=External gas
valve
0=50Hz
5 seconds
CIPREA D AS
10
5°C/minute
2 minutes
6 minutes
85°C
100%
1=Linked to set point
30 seconds
50°C
70°C
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ciprea 32 d asCiprea d 24 as

Tabla de contenido