TRABAJO ELÉCTRICO
Conexión del condensador
La conexión en el condensador
se desliza hacia la pala.
Electrical work
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install the air
conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110% of rated voltage.
3. The creepage protector and main power switch with a 1.5 times capacity of Max. Current of the unit
Conexión de manipulador del aire
should be installed in power circuit.
El manipulador de aire viene ya conectado
4. Ensure the air conditioner is grounded well.
de fábrica, no es necesario hacer la
5. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to
conexión.
connect the wire.
6. All wiring must comply with local and national electrical codes and be installed by qualified and skilled
electricians.
7. An individual branch circuit and single receptacle used only for this air conditioner must be available.
See the following table for suggested wire sizes and fuse specifications:
12
Cable de tierra
Use un tornillo para
conectar a tierra.