Installation

Cross-section of final installation

The WaterPro2 is designed to provide reliable fresh water to your livestock all year round.
When installing the WaterPro2 pay attention to the following areas:
Choose a location where the tank will be sheltered from the elements.
The vertical water supply line and the horizontal water supply line should all be installed to reach more
than 1 foot (305 mm) below the usual frost line.
The concrete slab should have a 4 inch (102 mm) by 18 inch (457 mm) apron from the tank to the concrete
edge.
Ensure that the placement of the water and electric access hole in the concrete aligns with the anticipated
placement of the water and electric access cavity of the waterer.
Make sure your vertical water supply line protrudes 10 inches (254 mm) above the concrete slab.
The water supply line should be centered in the thermal earth tube (if using) to help discourage frost
formation.
To be effective, the thermal earth tube(s)* must be installed to reach at least 1 foot (305 mm) below the
usual frost line.
Care should be taken to ensure the electric service below ground is installed outside of the thermal earth
tube.
It is recommended to caulk the base of the tank to prevent moisture and wind penetration.
In addition to the shut-off valve located inside the unit, we strongly recommend that a second, external shut-off valve
be installed outside of the concrete.
8
*Note that more than one thermal earth tube may be required.