CLEANING

Daily
Run the Pump Conditioning Program
The Pump Conditioning Program removes any moisture that may have
accumulated in the pump. During the program, the pump and oil reach
operating temperature, which evaporates any moisture in the pump.
1. Press
.
2. The display shows
3. Close the lid.
4. The program starts. Moving dots appear on the display.
5. The program runs for approximately 15 minutes. Do not interrupt
the program. If the program is interrupted, it must be run again to
ensure completion.
Clean the exterior and interior
WARNING
Electrical Shock Hazard
Keep water and other liquids from entering the inside of the
equipment. Liquid inside the equipment could cause an
electrical shock. Do not spray water or cleaning products.
Liquid could contact the electrical components and cause a
short circuit or an electrical shock.
CAUTION
Burn Hazard
Allow equipment to cool before moving or cleaning.
NOTICE: Do not use cleaners containing ammonia, alcohol, acetone
or dry cleaning products. Cleaners with these chemicals
will damage Plexiglas
will damage the finish.
NOTICE: Do not use paper towels, abrasive materials, scratching
cleansers, razor blades, brushes, steel wool or scouring
pads, such as Scotch Brite™ pads.These will damage the
finish.
®
NOTICE: Do not use WD-40
or petroleum, industrial or commercial
cleaning products. These will damage the finish.
1. Unplug the machine. Allow it to cool.
2. Wipe the vacuum chamber, lid, sealing bar, silicone holder and
exterior with a soft, lint free or microfiber cloth and warm water, or
a mixture of warm water and a small amount of mild dish
detergent.
3. Thoroughly wipe off any mild soap or chemical cleaners. Residue
could corrode the surface of the unit.
6
.
®
, acrylic and other plastics. These
Vacuum Packing Machine with Dual 16" Sealing Bars Operator's Manual

MAINTENANCE

WARNING
Electrical Shock Hazard
Unplug unit before servicing.
NOTICE: All maintenance must be performed by a qualified service
technician.
NOTICE: Do NOT tilt the machine. Tilting could enable oil to flow out
of the pump and cause damage to the machine.
The following maintenance schedule is only a guideline. Actual
maintenance needs will vary depending on machine use. Inspect your
machine regularly.
Interval
Procedure
Weekly
Check the oil by viewing the Oil Inspection Window.
Inspect the seal bar for wear.
Inspect the seal pad under the lid for wear.
Inspect the lid gasket and lid.
Every six
Replace the oil in the vacuum pump. Contact Vollrath
months
Technical Services.
Replace the sealing wires and Teflon
Replace the seal pad under the lid.
Replace the lid gasket.
Yearly
Inspect the oil exhaust filter. Contact Vollrath Technical
Services.
Every four
Replace the lid, gas springs and seal cylinder
years
membranes. Contact Vollrath Technical Services.
Replace the Sealing Wires and Teflon® Tape
Check the sealing bar for damage. Replace the Teflon tape or sealing
wires if the seal quality is no longer sufficient or if the Teflon tape or
seal wires are worn.
Tools Needed:
• Phillips screwdriver
• Tensioning tool or pliers
• Scissors
• Lint-free cleaning cloth
• Replacement Teflon tape
• Replacement sealing wire
1. Pull up on the sealing bar to remove it from the machine.
2. Remove the Teflon tape that protects the sealing wires.
®